Main INDEX
Monthly INDEX
PREV
NEXT
User name jiang
Log entry time 21:55:37 on August 14,1998
Entry number 204
This entry is a followup to: 203
keyword=Helicity scheme elogs
Some machine ops e log entries related to the helicity elog #203 in hall a logbook...
For helicity scheme changes, please refer to the MCC log entries #49157
Included here:
-------------------------------------------------------
User name Hansknecht
Log entry time 19:04:02 on August 14,1998
Entry number 49157
keyword=helicity controls
The helicity controller has been replaced with a newer improved unit. The Halls are receiving two signals: "HELICITY" and "CLOCK". The
helicity signal is a real time indication of the helicity being produced by the source. The clock signal is the line locked source for helicity state
decisions. Helicity state changes will occur during the rising edge of the clock signal. The controller is set in the pseudo-random mode at .5
hz. 5 MeV Mott measurements can now be done in the pseudo-random mode.
-------------------------------------------------------
Please also see MCC log #49156 as included below:
Entry number 49156
keyword=Mott Measurements Injector Tune Entry
Performed bunchlength procedure before beginning Mott.
Mott runs completed 1810. Someone realized the present setup provides longitudinal polarized electrons to hall C and B (not A). Discussion
ensued about making a spin change to be longit. to C and A. 1845: restoring beam to C, Chao checking locks.
Downtime = 16:00 Uptime = 16:00 Restoretime = 19:00
System = Injector Location = PGUN Device = MOTT
Cater # ______