Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 20:23:05 on August 16, 1998
Entry number 355
keyword=End_of_Run_2597
****************************
Run Number: 2597
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 291.152 Hz | 288.862 Hz | 580.097 Hz
2 | 14.3884 Hz | 14.2382 Hz | 28.6294 Hz
3 | 756.0 Hz | 751.585 Hz | 1507.8 Hz
4 | 895.621 Hz | 891.568 Hz | 1787.47 Hz
5 | 249.641 Hz | 247.736 Hz | 497.446 Hz
output | 217.782 Hz | 216.198 Hz | 434.005 Hz
Total number of output triggers = 6.21217e+05
Time of run = 23.856 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.375866 Hz | 0.0 Hz | 0.375866 Hz
- | 0.0 Hz | 0.37377 Hz | 0.37377 Hz
****************************
End-of-run EPICS data for Run Number 2597 at Sun Aug 16 20:22:58 EDT 1998
Electron Q1 power supply current : 892.78
Electron Q1 momentum : 1.19321
Electron Q1 gauss meter : -0.07563
Electron Q1 power supply polarity : Illegal Value
Electron Q2 power supply current : 510.998
Electron Q2 momentum : 1.19324
Electron Q2 gauss meter : 0.26934
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 0
Electron D1 momentum : 1.19282
Electron D1 NMR : 0.439444
Electron Q3 power supply current : 472.655
Electron Q3 momentum : 1.19375
Electron Q3 gauss meter : -0.23493
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 948.57
Hadron Q1 momentum : 1.2684
Hadron Q1 gauss meter : 0.023981
Hadron Q2 power supply current : 542.979
Hadron Q2 momentum : 1.2686
Hadron Q2 gauss meter : -0.2854
Hadron Q2 power supply polarity : 1
Hadron D1 power supply current : 433.073
Hadron D1 momentum : 1.26843
Hadron D1 NMR : 0.468124
Hadron Q3 power supply current : 501.825
Hadron Q3 momentum : 1.26809
Hadron Q3 gauss meter : -0.22464
Hadron Q3 power supply polarity : 0
Average current of the two cavities : 0.035085
Current on Unser monitor : -5.54572
Current on Upstream bcm : 0.0322193
Current on Downstream bcm : 0.0363516
Upstream Cavity Coefficient : 24.2901
Downstream Cavity Coefficient : 25.9484