Log entry time 02:30:22 on August 20, 1998
Entry number 645
keyword=End_of_Run_2703
****************************
Run Number: 2703
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 943.939 Hz | 944.056 Hz | 1888.27 Hz
2 | 33.6323 Hz | 33.336 Hz | 66.9827 Hz
3 | 443.66 Hz | 443.583 Hz | 887.408 Hz
4 | 773.036 Hz | 772.108 Hz | 1545.35 Hz
5 | 251.098 Hz | 250.524 Hz | 501.714 Hz
output | 236.22 Hz | 235.315 Hz | 471.563 Hz
Total number of output triggers = 3.58156e+05
Time of run = 12.6585 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.381826 Hz | 0.0 Hz | 0.377876 Hz
- | 0.0 Hz | 0.366026 Hz | 0.366026 Hz
****************************
End-of-run EPICS data for Run Number 2703 at Thu Aug 20 02:30:12 EDT 1998
Electron Q1 power supply current : 2106.65
Electron Q1 momentum : 2.81556
Electron Q1 gauss meter : -0.17854
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 1205.61
Electron Q2 momentum : 2.81524
Electron Q2 gauss meter : 0.6352
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 973.468
Electron D1 momentum : 2.81468
Electron D1 NMR : 1.03635
Electron Q3 power supply current : 1114.77
Electron Q3 momentum : 2.8156
Electron Q3 gauss meter : -0.5552
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1093.85
Hadron Q1 momentum : 1.46272
Hadron Q1 gauss meter : 0.02762
Hadron Q1 power supply polarity : 1
Hadron Q2 power supply current : 625.903
Hadron Q2 momentum : 1.46234
Hadron Q2 gauss meter : -0.3293
Hadron Q2 power supply polarity : 1
Hadron D1 power supply current : 498.393
Hadron D1 momentum :
Hadron D1 NMR : 0.539751
Hadron Q3 power supply current : 578.576
Hadron Q3 momentum : 1.46204
Hadron Q3 gauss meter : -0.2592
Hadron Q3 power supply polarity : 0
Average current of the two cavities : 9.85045
Current on Unser monitor : 4.45896
Current on Upstream bcm : 9.61778
Current on Downstream bcm : 10.0831
Upstream Cavity Coefficient : 24.2901
Downstream Cavity Coefficient : 25.9484