Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 04:23:01 on August 20, 1998
Entry number 656
keyword=End_of_Run_2706
****************************
Run Number: 2706
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 833.598 Hz | 832.047 Hz | 1665.88 Hz
2 | 30.2667 Hz | 30.0145 Hz | 60.2892 Hz
3 | 393.942 Hz | 394.014 Hz | 788.062 Hz
4 | 703.342 Hz | 702.072 Hz | 1405.61 Hz
5 | 222.135 Hz | 222.041 Hz | 444.236 Hz
output | 211.896 Hz | 211.831 Hz | 423.747 Hz
Total number of output triggers = 1.27903e+06
Time of run = 50.3062 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.385307 Hz | 0.0 Hz | 0.382988 Hz
- | 0.0 Hz | 0.376362 Hz | 0.376362 Hz
****************************
End-of-run EPICS data for Run Number 2706 at Thu Aug 20 04:22:45 EDT 1998
Electron Q1 power supply current : 2106.54
Electron Q1 momentum : 2.81542
Electron Q1 gauss meter : -0.17855
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 1205.75
Electron Q2 momentum : 2.81557
Electron Q2 gauss meter : 0.6352
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 973.468
Electron D1 momentum : 2.81565
Electron D1 NMR : 1.17961
Electron Q3 power supply current : 1114.78
Electron Q3 momentum : 2.81552
Electron Q3 gauss meter : -0.5552
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1093.85
Hadron Q1 momentum : 1.46272
Hadron Q1 gauss meter : 0.02765
Hadron Q1 power supply polarity : 1
Hadron Q2 power supply current : 626.01
Hadron Q2 momentum : 1.4626
Hadron Q2 gauss meter : -0.3293
Hadron Q2 power supply polarity : 1
Hadron D1 power supply current : 498.394
Hadron D1 momentum : 1.46251
Hadron D1 NMR : 0.539751
Hadron Q3 power supply current : 579.019
Hadron Q3 momentum : 1.46316
Hadron Q3 gauss meter : 1
Hadron Q3 power supply polarity : 0
Average current of the two cavities : 9.4423
Current on Unser monitor : 3.0005
Current on Upstream bcm : 9.22047
Current on Downstream bcm : 9.65415
Upstream Cavity Coefficient : 24.2901