• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 07:40:06 on August 20, 1998

    Entry number 665

    keyword=End_of_Run_2710
    ****************************
     Run Number: 2710
    End of Run Comment:
    Lost communication with target control system. Beam turned off,
    run ended.
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  744.103  Hz     |    745.401 Hz   |  1489.74 Hz
        2      |  27.3098  Hz     |    27.313 Hz   |  54.631 Hz
        3      |  351.379  Hz     |    352.239 Hz   |  703.73 Hz
        4      |  646.648  Hz     |    647.535 Hz   |  1294.35 Hz
        5      |  198.144  Hz     |    198.279 Hz   |  396.491 Hz
        output |  190.71  Hz   |    190.992 Hz |  381.724 Hz
     Total number of output triggers =     7.01506e+05 
     Time of run = 30.6288 min
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  0.38689  Hz         |    0.0 Hz        |  0.38417 Hz
          -        |  0.0  Hz        |    0.374375 Hz       |  0.374375 Hz
    
    ****************************
    End-of-run EPICS data for Run Number 2710 at Thu Aug 20 07:40:04 EDT 1998
    Electron Q1 power supply current        : 2106.58
    Electron Q1 momentum                    : 2.81547
    Electron Q1 gauss meter                 : -0.17856
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 1205.79
    Electron Q2 momentum                    : 2.81566
    Electron Q2 gauss meter                 : 0.6353
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 973.47
    Electron D1 momentum                    : 2.81471
    Electron D1 NMR                         : 1.03635
    Electron Q3 power supply current        : 1114.85
    Electron Q3 momentum                    : 2.81569
    Electron Q3 gauss meter                 : -0.5552
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 1093.75
    Hadron Q1 momentum                      : 1.46258
    Hadron Q1 gauss meter                   : 0.02764
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 625.952
    Hadron Q2 momentum                      : 1.46246
    Hadron Q2 gauss meter                   : -0.3293
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 498.394
    Hadron D1 momentum                      : 1.46251
    Hadron D1 NMR                           : 0.539751
    Hadron Q3 power supply current          : 578.817
    Hadron Q3 momentum                      : 1.46267
    Hadron Q3 gauss meter                   : -0.2593
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0334731
    Current on Unser monitor                : -5.64441
    Current on Upstream bcm                 : 0.0328803
    Current on Downstream bcm               : 0.0340659
    Upstream Cavity Coefficient             : 24.2901
    Downstream Cavity Coefficient           : 25.9484