Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 07:40:06 on August 20, 1998
Entry number 665
keyword=End_of_Run_2710
****************************
Run Number: 2710
End of Run Comment:
Lost communication with target control system. Beam turned off,
run ended.
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 744.103 Hz | 745.401 Hz | 1489.74 Hz
2 | 27.3098 Hz | 27.313 Hz | 54.631 Hz
3 | 351.379 Hz | 352.239 Hz | 703.73 Hz
4 | 646.648 Hz | 647.535 Hz | 1294.35 Hz
5 | 198.144 Hz | 198.279 Hz | 396.491 Hz
output | 190.71 Hz | 190.992 Hz | 381.724 Hz
Total number of output triggers = 7.01506e+05
Time of run = 30.6288 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.38689 Hz | 0.0 Hz | 0.38417 Hz
- | 0.0 Hz | 0.374375 Hz | 0.374375 Hz
****************************
End-of-run EPICS data for Run Number 2710 at Thu Aug 20 07:40:04 EDT 1998
Electron Q1 power supply current : 2106.58
Electron Q1 momentum : 2.81547
Electron Q1 gauss meter : -0.17856
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 1205.79
Electron Q2 momentum : 2.81566
Electron Q2 gauss meter : 0.6353
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 973.47
Electron D1 momentum : 2.81471
Electron D1 NMR : 1.03635
Electron Q3 power supply current : 1114.85
Electron Q3 momentum : 2.81569
Electron Q3 gauss meter : -0.5552
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1093.75
Hadron Q1 momentum : 1.46258
Hadron Q1 gauss meter : 0.02764
Hadron Q1 power supply polarity : 1
Hadron Q2 power supply current : 625.952
Hadron Q2 momentum : 1.46246
Hadron Q2 gauss meter : -0.3293
Hadron Q2 power supply polarity : 1
Hadron D1 power supply current : 498.394
Hadron D1 momentum : 1.46251
Hadron D1 NMR : 0.539751
Hadron Q3 power supply current : 578.817
Hadron Q3 momentum : 1.46267
Hadron Q3 gauss meter : -0.2593
Hadron Q3 power supply polarity : 0
Average current of the two cavities : 0.0334731
Current on Unser monitor : -5.64441
Current on Upstream bcm : 0.0328803
Current on Downstream bcm : 0.0340659
Upstream Cavity Coefficient : 24.2901