Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 22:00:18 on September 26, 1998
Entry number 1553
keyword=End_of_Run_1249
****************************
Run Number: 1249
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 1.16058 Hz | 1.25221 Hz | 2.41279 Hz
2 | 3.39012 Hz | 4.06204 Hz | 7.4827 Hz
3 | 1.61871 Hz | 1.37437 Hz | 2.99308 Hz
4 | 3.84824 Hz | 3.60391 Hz | 7.45216 Hz
5 | 0.0 Hz | 0.0 Hz | 0.0 Hz
output | 0.0305416 Hz | 0.0305416 Hz | 0.0610833 Hz
Total number of output triggers = 2.00000e+00
Time of run = 0.545703 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.397041 Hz | 0.0 Hz | 0.397041 Hz
- | 0.0 Hz | 0.427583 Hz | 0.427583 Hz
****************************
End-of-run EPICS data for Run Number 1249 at Sat Sep 26 22:00:13 EDT 1998
Electron Q1 power supply current : 1271.8
Electron Q1 momentum : 1.69977
Electron Q1 gauss meter : -0.10775
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 728.143
Electron Q2 momentum : 1.7003
Electron Q2 gauss meter : 0.3834
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 569.011
Electron D1 momentum : 1.70004
Electron D1 NMR : 0.6257
Electron Q3 power supply current : 673.056
Electron Q3 momentum : 1.69989
Electron Q3 gauss meter : -0.3343
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1271.38
Hadron Q1 momentum : 1.7001
Hadron Q1 gauss meter : -0.03182
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 727.799
Hadron Q2 momentum : 1.70041
Hadron Q2 gauss meter : 0.3814
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 601.678
Hadron D1 momentum : 1.64744
Hadron D1 NMR : 0.608002
Hadron Q3 power supply current : 672.627
Hadron Q3 momentum : 1.6997
Hadron Q3 gauss meter : 0.3012
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 0.018671
Current on Unser monitor : 3.25898
Current on Upstream bcm : 0
Current on Downstream bcm : 0.037342
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 27.604