Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:47:37 on September 27, 1998
Entry number 1581
keyword=End_of_Run_1261
****************************
Run Number: 1261
End of Run Comment:
Normal end of run raster 4mm y knob at max
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 618.402 Hz | 613.571 Hz | 1232.11 Hz
2 | 84.4935 Hz | 85.1914 Hz | 169.698 Hz
3 | 334.042 Hz | 333.814 Hz | 667.99 Hz
4 | 31.9132 Hz | 31.2288 Hz | 63.1554 Hz
5 | 0.0805211 Hz | 0.0402606 Hz | 0.120782 Hz
output | 160.935 Hz | 156.506 Hz | 317.455 Hz
Total number of output triggers = 2.36550e+04
Time of run = 1.24191 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.429446 Hz | 0.0 Hz | 0.429446 Hz
- | 0.0 Hz | 0.429446 Hz | 0.429446 Hz
****************************
End-of-run EPICS data for Run Number 1261 at Sun Sep 27 01:47:35 EDT 1998
Electron Q1 power supply current : 1271.83
Electron Q1 momentum : 1.69982
Electron Q1 gauss meter : -0.10775
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 727.86
Electron Q2 momentum : 1.69964
Electron Q2 gauss meter : 0.3833
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 568.885
Electron D1 momentum : 1.70001
Electron D1 NMR : 0.625691
Electron Q3 power supply current : 673.163
Electron Q3 momentum : 1.70016
Electron Q3 gauss meter : -0.3344
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1271.41
Hadron Q1 momentum : 1.70015
Hadron Q1 gauss meter : -0.03184
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 727.627
Hadron Q2 momentum : 1.70001
Hadron Q2 gauss meter : 0.3814
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 583.304
Hadron D1 momentum : 1.7
Hadron D1 NMR : 0.627399
Hadron Q3 power supply current : 672.779
Hadron Q3 momentum : 1.70009
Hadron Q3 gauss meter : 0.3012
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 1.27039
Current on Unser monitor : 5.52124
Current on Upstream bcm : 0
Current on Downstream bcm : 2.55519
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 27.604