Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:19:07 on September 27, 1998
Entry number 1674
keyword=End_of_Run_1300
****************************
Run Number: 1300
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 14006.0 Hz | 14424.2 Hz | 28434.2 Hz
2 | 939.875 Hz | 971.513 Hz | 1911.63 Hz
3 | 12827.8 Hz | 13189.5 Hz | 26020.9 Hz
4 | 608.965 Hz | 630.291 Hz | 1239.42 Hz
5 | 52.8752 Hz | 55.6868 Hz | 108.529 Hz
output | 1089.73 Hz | 975.258 Hz | 2064.43 Hz
Total number of output triggers = 1.85769e+05
Time of run = 1.49976 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.400065 Hz | 0.0 Hz | 0.400065 Hz
- | 0.0 Hz | 0.400065 Hz | 0.400065 Hz
****************************
End-of-run EPICS data for Run Number 1300 at Sun Sep 27 23:19:05 EDT 1998
Electron Q1 power supply current : 897.575
Electron Q1 momentum : 1.19962
Electron Q1 gauss meter : -0.07615
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 513.774
Electron Q2 momentum : 1.19972
Electron Q2 gauss meter : 0.2709
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 398.718
Electron D1 momentum : 1.20098
Electron D1 NMR : 0.442152
Electron Q3 power supply current : 475.192
Electron Q3 momentum : 1.20016
Electron Q3 gauss meter : -0.2358
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 897.435
Hadron Q1 momentum : 1.20007
Hadron Q1 gauss meter : -0.02255
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 513.431
Hadron Q2 momentum : 1.19957
Hadron Q2 gauss meter : 0.2694
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 408.058
Hadron D1 momentum : 1.2
Hadron D1 NMR : 0.44287
Hadron Q3 power supply current : 474.66
Hadron Q3 momentum : 1.19945
Hadron Q3 gauss meter : 0.21221
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 0.483306
Current on Unser monitor : 3.77193
Current on Upstream bcm : 0
Current on Downstream bcm : 0.966612
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 27.604