Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:34:02 on September 28, 1998
Entry number 1809
keyword=End_of_Run_1375
****************************
Run Number: 1375
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 51.7119 Hz | 50.8554 Hz | 102.581 Hz
2 | 6.31009 Hz | 6.26299 Hz | 12.5751 Hz
3 | 50.9923 Hz | 50.2817 Hz | 101.288 Hz
4 | 5.87511 Hz | 5.883 Hz | 11.7606 Hz
5 | 0.056538 Hz | 0.0590482 Hz | 0.115706 Hz
output | 1.5882 Hz | 1.57757 Hz | 3.16583 Hz
Total number of output triggers = 5.29710e+04
Time of run = 278.868 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.380885 Hz | 0.0 Hz | 0.379928 Hz
- | 0.0 Hz | 0.375685 Hz | 0.375685 Hz
****************************
End-of-run EPICS data for Run Number 1375 at Mon Sep 28 23:34:00 EDT 1998
Electron Q1 power supply current : 1202.35
Electron Q1 momentum : 1.60696
Electron Q1 gauss meter : -0.10191
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 688.056
Electron Q2 momentum : 1.60669
Electron Q2 gauss meter : 0.3625
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 536.516
Electron D1 momentum : 1.607
Electron D1 NMR : 0.591481
Electron Q3 power supply current : 636.307
Electron Q3 momentum : 1.60708
Electron Q3 gauss meter : -0.316
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1201.72
Hadron Q1 momentum : 1.60697
Hadron Q1 gauss meter : -0.03011
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 687.707
Hadron Q2 momentum : 1.60674
Hadron Q2 gauss meter : 0.3607
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 549.789
Hadron D1 momentum : 1.607
Hadron D1 NMR : 0.593077
Hadron Q3 power supply current : 635.7
Hadron Q3 momentum : 1.60639
Hadron Q3 gauss meter : 0.2846
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 14.4224
Current on Unser monitor : 34.4702
Current on Upstream bcm : 0
Current on Downstream bcm : 28.8448
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 27.604