Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 12:06:16 on September 29, 1998
Entry number 1891
keyword=End_of_Run_1411
****************************
Run Number: 1411
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 1707.56 Hz | 1720.45 Hz | 3428.52 Hz
2 | 86.3053 Hz | 87.1561 Hz | 173.488 Hz
3 | 1491.57 Hz | 1500.51 Hz | 2992.51 Hz
4 | 53.658 Hz | 53.7928 Hz | 107.465 Hz
5 | 0.701342 Hz | 0.766441 Hz | 1.47033 Hz
output | 1156.73 Hz | 1163.14 Hz | 2319.65 Hz
Total number of output triggers = 4.56096e+06
Time of run = 32.7705 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.377372 Hz | 0.0 Hz | 0.374829 Hz
- | 0.0 Hz | 0.369743 Hz | 0.369743 Hz
****************************
End-of-run EPICS data for Run Number 1411 at Tue Sep 29 12:06:14 EDT 1998
Electron Q1 power supply current : 1202.35
Electron Q1 momentum : 1.60696
Electron Q1 gauss meter : -0.1019
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 688.079
Electron Q2 momentum : 1.60674
Electron Q2 gauss meter : 0.3624
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 536.518
Electron D1 momentum : 1.60701
Electron D1 NMR : 0.673478
Electron Q3 power supply current : 636.37
Electron Q3 momentum : 1.60723
Electron Q3 gauss meter : -0.316
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1201.83
Hadron Q1 momentum : 1.60711
Hadron Q1 gauss meter : -0.03011
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 687.727
Hadron Q2 momentum : 1.60679
Hadron Q2 gauss meter : 0.3608
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 549.789
Hadron D1 momentum : 1.607
Hadron D1 NMR : 0.593077
Hadron Q3 power supply current : 635.807
Hadron Q3 momentum : 1.60666
Hadron Q3 gauss meter : 0.2846
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 1.50595
Current on Unser monitor : 6.03169
Current on Upstream bcm : 0
Current on Downstream bcm : 3.03037
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 28.1