Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 18:27:20 on September 29, 1998
Entry number 1910
keyword=End_of_Run_1415
****************************
Run Number: 1415
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 131.32 Hz | 131.222 Hz | 262.584 Hz
2 | 35.0949 Hz | 35.1398 Hz | 70.2434 Hz
3 | 125.919 Hz | 126.139 Hz | 252.095 Hz
4 | 30.0992 Hz | 30.0677 Hz | 60.1756 Hz
5 | 0.00797047 Hz | 0.00543441 Hz | 0.0134049 Hz
output | 236.008 Hz | 236.485 Hz | 472.501 Hz
Total number of output triggers = 2.60838e+06
Time of run = 92.0063 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.384032 Hz | 0.0 Hz | 0.382582 Hz
- | 0.0 Hz | 0.375155 Hz | 0.375155 Hz
****************************
End-of-run EPICS data for Run Number 1415 at Tue Sep 29 18:27:18 EDT 1998
Electron Q1 power supply current : 1202.21
Electron Q1 momentum : 1.60677
Electron Q1 gauss meter : -0.10189
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 688.182
Electron Q2 momentum : 1.60698
Electron Q2 gauss meter : 0.3625
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 536.579
Electron D1 momentum : 1.607
Electron D1 NMR : 0.673475
Electron Q3 power supply current : 636.223
Electron Q3 momentum : 1.60686
Electron Q3 gauss meter : -0.3161
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1201.8
Hadron Q1 momentum : 1.60706
Hadron Q1 gauss meter : -0.0301
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 687.646
Hadron Q2 momentum : 1.6066
Hadron Q2 gauss meter : 0.3607
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 549.79
Hadron D1 momentum : 1.607
Hadron D1 NMR : 0.593077
Hadron Q3 power supply current : 636.008
Hadron Q3 momentum : 1.60717
Hadron Q3 gauss meter : 0.2847
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 0.0193164
Current on Unser monitor : 3.43032
Current on Upstream bcm : 0
Current on Downstream bcm : 0.0386328
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 28.1