Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:34:04 on September 29, 1998
Entry number 1924
keyword=End_of_Run_1419
****************************
Run Number: 1419
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 1735.23 Hz | 1746.01 Hz | 3481.73 Hz
2 | 88.6313 Hz | 88.7709 Hz | 177.427 Hz
3 | 1525.81 Hz | 1535.95 Hz | 3062.22 Hz
4 | 55.4657 Hz | 56.2348 Hz | 111.717 Hz
5 | 0.750559 Hz | 0.786638 Hz | 1.53897 Hz
output | 1226.32 Hz | 1230.33 Hz | 2456.41 Hz
Total number of output triggers = 8.30630e+06
Time of run = 56.358 min
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 0.381194 Hz | 0.0 Hz | 0.379124 Hz
- | 0.0 Hz | 0.372026 Hz | 0.372026 Hz
****************************
End-of-run EPICS data for Run Number 1419 at Tue Sep 29 23:34:02 EDT 1998
Electron Q1 power supply current : 1202.11
Electron Q1 momentum : 1.60663
Electron Q1 gauss meter : -0.1019
Electron Q1 power supply polarity : 0
Electron Q2 power supply current : 688.285
Electron Q2 momentum : 1.60722
Electron Q2 gauss meter : 0.3624
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 536.649
Electron D1 momentum : 1.60701
Electron D1 NMR : 0.591485
Electron Q3 power supply current : 636.369
Electron Q3 momentum : 1.60723
Electron Q3 gauss meter : -0.316
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 1201.8
Hadron Q1 momentum : 1.60706
Hadron Q1 gauss meter : -0.03011
Hadron Q1 power supply polarity : 0
Hadron Q2 power supply current : 687.837
Hadron Q2 momentum : 1.60705
Hadron Q2 gauss meter : 0.3608
Hadron Q2 power supply polarity : 0
Hadron D1 power supply current : 549.781
Hadron D1 momentum : 1.607
Hadron D1 NMR : 0.593076
Hadron Q3 power supply current : 635.908
Hadron Q3 momentum : 1.60691
Hadron Q3 gauss meter : 0.2847
Hadron Q3 power supply polarity : 1
Average current of the two cavities : 1.47914
Current on Unser monitor : 7.53904
Current on Upstream bcm : 0
Current on Downstream bcm : 2.95828
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 28.1