0800 | 0900 | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | Total Time | |
---|---|---|---|---|---|---|---|---|---|
Acceptable Beam in Use | 50 | 5 | 0 | 0 | 45 | 1 | 1 | 45 | 4.41666666666667 |
Beam Available but Not in Use | 10 | 55 | 1 | 1 | 15 | 0 | 0 | 15 | 3.58333333333333 |
Beam Not Available or Unacceptable | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Accelerator Con- figuration Chage | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Experiment Ready | 50 | 5 | 0 | 0 | 45 | 1 | 1 | 45 | 4.41666666666667 |
Planned Config- uration Change | 10 | 55 | 1 | 1 | 15 | 0 | 0 | 15 | 3.58333333333333 |
Unplanned Experiment Down | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Hall not ready reasons | |||||||||
Target | 0 | 20 | 0 | 0 | 15 | 0 | 0 | 0 | 0.583333333333333 |
HRSe | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
HRSh | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Data Acq | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Other | 10 | 35 | 1 | 1 | 0 | 0 | 0 | 15 | 3 |
Comments: 8:40 End |_ runs @ E=3.4 GeV, Ep=2.580 GeV, Theta=15.5 degree Tot # of events 27.8 M 8:43 Compton polarimeter checked the charge asymmetry prior to change the pockel cell voltage : Aq=680 ppm. 8:55 change momentum to P=2.382 GeV/c. Problem with hadron arm magnets 9:00 NMR measurement: target polarisation (transverse): 33 % 9:25 Compton checked charge asymmetry after to have change the PC cell current: -37 +/-24 ppm 9:30 BCM linearity tests + BCM calibration. Ended at 11:50 12:00 NMR: target polarisation (longitudinal) 34 % 12:20 begin \\ runs @ E=3.4 GeV, P=2.382 GeV/c 13:00 notice a light leak in the scintillators. Should not affect the data quality 13:00 pedestal run 15:15 back to // runs.
Data Entry by: Deur A.