• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Eugene

    Log entry time 23:18:06 on December 15,1998

    Entry number 8713

    Followups:

    keyword=Moller quad settings

    The Moller quads were set by MCC to :
    MQM1H02 18050 100A
    MQO1H03 -12630 75A
    MQO1H03A 26840 160A
    which is a unified setting for both Moller and regular running.

    The power supplies for 1H02 were found turned off and 1H03A was at about
    130A instead of 160A. It looks like this setting ran across some limitation,
    though the limit for a couple of power supplies, working in parallel should be about
    240A, well above 160A. EPICS somehow managed to read out 18A from
    the turned off power supplies!
    We decided to run this Moller measurement at a different
    setting:
    MQM1H02 8120 43A
    MQO1H03 3610 20A
    MQO1H03A 15810 93A
    which are equally good for Moller and , accordingly to Jay Benesch ,
    acceptable for regular running.

    One should contact Jay and H.Areti tomorrow.