    keyword=scaler cable replacement

    Replaced the 34-pin flat cables that fanout the signals
    for the normalization scalers (charge, triggers, etc) on
    the H-spectrometer. There was fairly good evidence that
    the d10 anomaly was traceable to one or more bad cables
    at this fanout. The connectors can be intermittent.

    Wang and I did some test runs. The sum rule between
    + and - helicity seems violated now by u1 and d1 charge !!
    We see "+ " is about same as sum, and "-" is ~0.5*sum.
    On E-arm, the sum rule is satisfied for these. Will investigate...