• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 20:36:01 on July 16, 1999

    Entry number 22840

    keyword=End_of_Run_284
    ****************************
     Run Number: 284
    End of Run Comment:
    Tar=LH2,Type=elastic,Ene=3317.6,Eangle=12.527,Hangle=12.56
    beam is off by a lot, 5 mm in horizontal.
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  34426.634  Hz     |    34385.904 Hz   |  34418.848 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        3      |  36482.438  Hz     |    36577.177 Hz   |  36558.242 Hz
        4      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        5      |  149.76302  Hz     |    154.70103 Hz   |  152.26136 Hz
        output |  4317.8573  Hz   |    4315.8335 Hz |  4318.74 Hz
     Total number of output triggers =     9.43670e+04 
     Number of raw T1 752072.0  ; Number of raw T3 798819.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 0.36417643 min
     Time of run h- = 0.17937825 min
     Time of run h+ = 0.17939453 min
     1-(sum of time hel + and -)/( run time) = 1.4838e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  0.0  Hz         |    0.0 Hz        |  15.011039 Hz
          -        |  0.0  Hz        |    0.0 Hz       |  15.011039 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0000309         |   0.0000309         | 0.0000628     
       upstream 3x |   0.0000313         |   0.0000313         | 0.0000635     
       upstream 10x|   0.0000317         |   0.0000317         | 0.0000644     
      downstream   |   0.0000309         |   0.0000309         | 0.0000627    
     downstream 3x |   0.0000315         |   0.0000315         | 0.0000639    
     downstream 10x|   0.0000316         |   0.0000315         | 0.0000641    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   0.00000000e+00 
       upstream 3x |   0.00000000e+00 
       upstream 10x|   0.00000000e+00 
      downstream   |   0.00000000e+00 
     downstream 3x |   0.00000000e+00 
     downstream 10x|   -1.58478610e-03 
     
    
    ****************************
    End-of-run EPICS data for Run Number 284 at Fri Jul 16 20:35:58 EDT 1999
    Electron Q1 power supply current        : 2289.56
    Electron Q1 momentum                    : 3.06002
    Electron Q1 gauss meter                 : -0.19409
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 1310.46
    Electron Q2 momentum                    : 3.06008
    Electron Q2 gauss meter                 : 0.6902
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 1066.86
    Electron D1 momentum                    : 3.06001
    Electron D1 NMR                         : 1.1269
    Electron Q3 power supply current        : 1211.67
    Electron Q3 momentum                    : 3.06023
    Electron Q3 gauss meter                 : -0.6034
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 2268.98
    Hadron Q1 momentum                      : 3.03412
    Hadron Q1 gauss meter                   : -0.05666
    Hadron Q1 power supply polarity         : 0
    Hadron Q2 power supply current          : 1298.68
    Hadron Q2 momentum                      : 3.03421
    Hadron Q2 gauss meter                   : 0.6819
    Hadron Q2 power supply polarity         : 0
    Hadron D1 power supply current          : 1083.26
    Hadron D1 momentum                      : 3.0342
    Hadron D1 NMR                           : 1.1198
    Hadron Q3 power supply current          : 1200.68
    Hadron Q3 momentum                      : 3.03407
    Hadron Q3 gauss meter                   : 0.538
    Hadron Q3 power supply polarity         : 1
    Average current of the two cavities     : 2.98349
    Current on Unser monitor                : -4.35356
    Current on Upstream bcm                 : 2.98865
    Current on Downstream bcm               : 2.97833
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             :