• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 05:03:43 on August 4, 1999

    Entry number 24194

    keyword=End_of_Run_694
    ****************************
     Run Number: 694
    End of Run Comment:
    Tar=absence,Type=Cosmic,Pmom=.65800,Rad=0,Ene=1.148,Angle_e=34.96,Angle_h=54.99
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  16.027869  Hz     |    16.312261 Hz   |  16.201074 Hz
        2      |  50.623408  Hz     |    50.809167 Hz   |  50.691203 Hz
        3      |  110.44928  Hz     |    110.71559 Hz   |  110.55365 Hz
        4      |  4906.0337  Hz     |    4915.9743 Hz   |  4910.973 Hz
        5      |  0.014794956  Hz     |    0.013151072 Hz   |  0.013763343 Hz
        output |  123.07266  Hz   |    123.54939 Hz |  123.30417 Hz
     Total number of output triggers =     1.52301e+05 
     Number of raw T1 20011.0  ; Number of raw T3 136552.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 20.586083 min
     Time of run h- = 10.13859 min
     Time of run h+ = 10.13859 min
     1-(sum of time hel + and -)/( run time) = 1.5005e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5002125  Hz         |    0.0 Hz        |  15.001235 Hz
          -        |  0.0  Hz        |    15.000425 Hz       |  15.001235 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0000310         |   0.0000315         | 0.0000632     
       upstream 3x |   0.0000442         |   0.0000443         | 0.0000899     
       upstream 10x|   0.0000564         |   0.0000565         | 0.0001146     
      downstream   |   0.0000410         |   0.0000416         | 0.0000836    
     downstream 3x |   0.0000555         |   0.0000557         | 0.0001130    
     downstream 10x|   0.0000580         |   0.0000581         | 0.0001179    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   8.00000000e-03 
       upstream 3x |   1.12994350e-03 
       upstream 10x|   8.85739590e-04 
      downstream   |   7.26392250e-03 
     downstream 3x |   1.79856120e-03 
     downstream 10x|   8.61326440e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 694 at Wed Aug  4 05:03:41 EDT 1999
    Electron Q1 power supply current        : 703.885
    Electron Q1 momentum                    : 0.940751
    Electron Q1 gauss meter                 : -0.05976
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 402.936
    Electron Q2 momentum                    : 0.940902
    Electron Q2 gauss meter                 : 0.213
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 311.982
    Electron D1 momentum                    : 0.940996
    Electron D1 NMR                         : 0.346496
    Electron Q3 power supply current        : 372.366
    Electron Q3 momentum                    : 0.940459
    Electron Q3 gauss meter                 : -0.18555
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 492.065
    Hadron Q1 momentum                      : 0.657998
    Hadron Q1 gauss meter                   : 0.012549
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 281.572
    Hadron Q2 momentum                      : 0.657857
    Hadron Q2 gauss meter                   : -0.1476
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 225.425
    Hadron D1 momentum                      : 0.658
    Hadron D1 NMR                           : 0.24284
    Hadron Q3 power supply current          : 260.537
    Hadron Q3 momentum                      : 0.658367
    Hadron Q3 gauss meter                   : -0.11635
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.013506
    Current on Unser monitor                : -5.8759
    Current on Upstream bcm                 : 0.0149735
    Current on Downstream bcm               : 0.0120386
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1148.17