• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 08:02:11 on August 4, 1999

    Entry number 24227

    keyword=End_of_Run_707
    ****************************
     Run Number: 707
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Pmom=.65800,Rad=0,Ene=1.148,Angle_e=34.96,Angle_h=54.99
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  6753.0841  Hz     |    6767.1893 Hz   |  6761.63 Hz
        2      |  104.89136  Hz     |    104.05054 Hz   |  104.462 Hz
        3      |  4035.7158  Hz     |    4036.9536 Hz   |  4037.5567 Hz
        4      |  4168.4505  Hz     |    4178.7999 Hz   |  4174.7351 Hz
        5      |  2024.8416  Hz     |    2028.2755 Hz   |  2027.0549 Hz
        output |  1390.7335  Hz   |    1392.6182 Hz |  1392.0125 Hz
     Total number of output triggers =     1.35745e+06 
     Number of raw T1 6593725.0  ; Number of raw T3 3937296.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 16.252799 min
     Time of run h- = 8.0044433 min
     Time of run h+ = 8.0043132 min
     1-(sum of time hel + and -)/( run time) = 1.5015e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5002463  Hz         |    0.0 Hz        |  15.002544 Hz
          -        |  0.0  Hz        |    15.001518 Hz       |  15.001518 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0020347         |   0.0020385         | 0.0041343     
       upstream 3x |   0.0020514         |   0.0020550         | 0.0041683     
       upstream 10x|   0.0020703         |   0.0020738         | 0.0042066     
      downstream   |   0.0020354         |   0.0020393         | 0.0041359    
     downstream 3x |   0.0020563         |   0.0020598         | 0.0041781    
     downstream 10x|   0.0020612         |   0.0020646         | 0.0041880    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   9.32927430e-04 
       upstream 3x |   8.76680300e-04 
       upstream 10x|   8.44574210e-04 
      downstream   |   9.57125680e-04 
     downstream 3x |   8.50319480e-04 
     downstream 10x|   8.24082600e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 707 at Wed Aug  4 08:02:05 EDT 1999
    Electron Q1 power supply current        : 703.815
    Electron Q1 momentum                    : 0.940657
    Electron Q1 gauss meter                 : -0.05975
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 403.051
    Electron Q2 momentum                    : 0.941171
    Electron Q2 gauss meter                 : 0.2131
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 311.986
    Electron D1 momentum                    : 0.940997
    Electron D1 NMR                         : 0.346496
    Electron Q3 power supply current        : 372.571
    Electron Q3 momentum                    : 0.940977
    Electron Q3 gauss meter                 : -0.18554
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 492.065
    Hadron Q1 momentum                      : 0.657998
    Hadron Q1 gauss meter                   : 0.012546
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 281.566
    Hadron Q2 momentum                      : 0.657844
    Hadron Q2 gauss meter                   : -0.14759
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 225.426
    Hadron D1 momentum                      : 0.658
    Hadron D1 NMR                           : 0.24284
    Hadron Q3 power supply current          : 260.551
    Hadron Q3 momentum                      : 0.658401
    Hadron Q3 gauss meter                   : -0.11639
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 4.37817
    Current on Unser monitor                : -1.40743
    Current on Upstream bcm                 : 4.38817
    Current on Downstream bcm               : 4.3718
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1148.17