• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 23:29:04 on August 4, 1999

    Entry number 24283

    keyword=End_of_Run_723
    ****************************
     Run Number: 723
    End of Run Comment:
    Tar=LD2-15cm,Type=Inelastic,Pmom=.65800,Rad=4,Ene=1.148,Angle_e=34.965,Angle_h=61.745
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  23471.921  Hz     |    23485.916 Hz   |  23482.857 Hz
        2      |  2804.596  Hz     |    2812.0245 Hz   |  2808.7159 Hz
        3      |  133.49224  Hz     |    135.07047 Hz   |  134.29896 Hz
        4      |  29420.995  Hz     |    29390.32 Hz   |  29412.652 Hz
        5      |  0.68719528  Hz     |    0.81518006 Hz   |  0.74885112 Hz
        output |  134.29499  Hz   |    135.73965 Hz |  135.02385 Hz
     Total number of output triggers =     4.50770e+04 
     Number of raw T1 7839628.0  ; Number of raw T3 44835.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 5.5640788 min
     Time of run h- = 2.739681 min
     Time of run h+ = 2.7406087 min
     1-(sum of time hel + and -)/( run time) = 1.5059e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5004928  Hz         |    0.0 Hz        |  15.003981 Hz
          -        |  0.0  Hz        |    15.000986 Hz       |  15.003981 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0023014         |   0.0023013         | 0.0046734     
       upstream 3x |   0.0023107         |   0.0023104         | 0.0046921     
       upstream 10x|   0.0023239         |   0.0023236         | 0.0047188     
      downstream   |   0.0022980         |   0.0022979         | 0.0046665    
     downstream 3x |   0.0023097         |   0.0023094         | 0.0046900    
     downstream 10x|   0.0023128         |   0.0023125         | 0.0046963    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -2.17263780e-05 
       upstream 3x |   -6.49196080e-05 
       upstream 10x|   -6.45508340e-05 
      downstream   |   -2.17585240e-05 
     downstream 3x |   -6.49477170e-05 
     downstream 10x|   -6.48606580e-05 
     
    
    ****************************
    End-of-run EPICS data for Run Number 723 at Wed Aug  4 23:29:03 EDT 1999
    Electron Q1 power supply current        : 703.885
    Electron Q1 momentum                    : 0.940751
    Electron Q1 gauss meter                 : -0.05975
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 402.982
    Electron Q2 momentum                    : 0.941009
    Electron Q2 gauss meter                 : 0.21225
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 311.985
    Electron D1 momentum                    : 0.940999
    Electron D1 NMR                         : 0.346497
    Electron Q3 power supply current        : 372.529
    Electron Q3 momentum                    : 0.940869
    Electron Q3 gauss meter                 : -0.18495
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 854.385
    Hadron Q1 momentum                      : 1.1425
    Hadron Q1 gauss meter                   : 0.021623
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 488.745
    Hadron Q2 momentum                      : 1.14189
    Hadron Q2 gauss meter                   : -0.25654
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 390.549
    Hadron D1 momentum                      : 1.1424
    Hadron D1 NMR                           : 0.421612
    Hadron Q3 power supply current          : 452.134
    Hadron Q3 momentum                      : 1.14252
    Hadron Q3 gauss meter                   : -0.20209
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.9977
    Current on Unser monitor                : 22.9512
    Current on Upstream bcm                 : 30.0213
    Current on Downstream bcm               : 29.9741
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1148.17