     Run Number: 764
    End of Run Comment:
    Tar=LD2-15cm,Type=Inelastic,Pmom=1.1424,Rad=6,Ene=1.148,Angle_e=34.965,Angle_h=61.745
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  38167.311  Hz     |    38159.456 Hz   |  38165.626 Hz
        2      |  5529.7323  Hz     |    5523.3049 Hz   |  5526.7853 Hz
        3      |  296.39314  Hz     |    294.98298 Hz   |  295.75143 Hz
        4      |  62705.633  Hz     |    62712.563 Hz   |  62718.897 Hz
        5      |  1.4563029  Hz     |    1.5203322 Hz   |  1.4933914 Hz
        output |  343.37209  Hz   |    342.24006 Hz |  342.86069 Hz
     Total number of output triggers =     6.86460e+05 
     Number of raw T1 76413473.0  ; Number of raw T3 592140.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 33.369238 min
     Time of run h- = 16.432813 min
     Time of run h+ = 16.43431 min
     1-(sum of time hel + and -)/( run time) = 1.5047e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5004209  Hz         |    0.0 Hz        |  15.001841 Hz
          -        |  0.0  Hz        |    15.001341 Hz       |  15.001341 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0232735         |   0.0232755         | 0.0472605     
       upstream 3x |   0.0233547         |   0.0233561         | 0.0474246     
       upstream 10x|   0.0234759         |   0.0234772         | 0.0476707     
      downstream   |   0.0232330         |   0.0232350         | 0.0471783    
     downstream 3x |   0.0233355         |   0.0233369         | 0.0473853    
     downstream 10x|   0.0233665         |   0.0233678         | 0.0474483    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   4.29654770e-05 
       upstream 3x |   2.99716550e-05 
       upstream 10x|   2.76872030e-05 
      downstream   |   4.30403720e-05 
     downstream 3x |   2.99963150e-05 
     downstream 10x|   2.78168280e-05 
     
    
    ****************************
    End-of-run EPICS data for Run Number 764 at Fri Aug  6 01:51:09 EDT 1999
    Electron Q1 power supply current        : 703.885
    Electron Q1 momentum                    : 0.940751
    Electron Q1 gauss meter                 : -0.05976
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 403.008
    Electron Q2 momentum                    : 0.941071
    Electron Q2 gauss meter                 : 0.21222
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 311.985
    Electron D1 momentum                    : 0.940997
    Electron D1 NMR                         : 0.346496
    Electron Q3 power supply current        : 372.481
    Electron Q3 momentum                    : 0.940748
    Electron Q3 gauss meter                 : -0.18492
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 854.385
    Hadron Q1 momentum                      : 1.1425
    Hadron Q1 gauss meter                   : 0.021627
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 488.991
    Hadron Q2 momentum                      : 1.14247
    Hadron Q2 gauss meter                   : -0.25662
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 390.556
    Hadron D1 momentum                      : 1.1424
    Hadron D1 NMR                           : 0.421612
    Hadron Q3 power supply current          : 452.119
    Hadron Q3 momentum                      : 1.14249
    Hadron Q3 gauss meter                   : -0.20213
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 25.4426
    Current on Unser monitor                : 18.0485
    Current on Upstream bcm                 : 25.517
    Current on Downstream bcm               : 25.3682
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1148.06