• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Saha

    Log entry time 09:21:39 on August 6,1999

    Entry number 24429

    keyword=Arc Energy Measurement - Aug 2, 99

    These are the results of the Arc Energy measurements for Aug 2, 1999

    We first made measurements with 5 uA cw, Achromatic beam tune

    BdL measurement (Achromatic mode): Run #434: I = 6623.32 T.mm
    Harp Scan (#1,2,3,4): Run #196 (shown on plot 1 below)

    We then went to Dispersive mode tune. 5 uA cw

    Harp scan # 197: Theta = 34.2964 degrees (shown in plot 2 below)
    Harp scan # 199: Theta = 34.2968 degrees

    BdL measurement (Dispersive mode): Run #435: I = 6623.39 T.mm
    BdL measurement (Dispersive mode): Run #436: I = 6623.38 T.mm

    Average BdL = 6623.385 T.mm
    Average angle = 34.2966 degrees = 0.598589 r

    The Energy = 3317.2 MeV +/- 0.5 MeV

    Comments:
    1. The Fast Feedback was on during this process and this is reflected in the compact beam envelopes with practically no jitter.





    FIGURE 1

    FIGURE 2