• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 15:47:00 on August 12, 1999

    Entry number 24795

    keyword=End_of_Run_926
    ****************************
     Run Number: 926
    End of Run Comment:
    Tar=dum-15cm,Type=Elastic,Pmom=0.484,Rad=0,Ene=857,Angle_e=42.29,Angle_h=55.77
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  71.283957  Hz     |    73.723604 Hz   |  72.416896 Hz
        2      |  20.85569  Hz     |    20.92497 Hz   |  20.86348 Hz
        3      |  212.88833  Hz     |    213.42749 Hz   |  213.23763 Hz
        4      |  2756.9584  Hz     |    2749.7878 Hz   |  2753.9528 Hz
        5      |  0.0090050476  Hz     |    0.0 Hz   |  0.004434321 Hz
        output |  328.16194  Hz   |    331.36905 Hz |  329.73167 Hz
     Total number of output triggers =     7.43590e+04 
     Number of raw T1 16331.0  ; Number of raw T3 48088.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 3.7585612 min
     Time of run h- = 1.851058 min
     Time of run h+ = 1.8508138 min
     1-(sum of time hel + and -)/( run time) = 1.5083e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.4984368  Hz         |    0.0 Hz        |  15.001308 Hz
          -        |  0.0  Hz        |    15.001308 Hz       |  15.001308 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0002746         |   0.0002747         | 0.0005576     
       upstream 3x |   0.0002780         |   0.0002779         | 0.0005645     
       upstream 10x|   0.0002817         |   0.0002816         | 0.0005719     
      downstream   |   0.0002755         |   0.0002755         | 0.0005594    
     downstream 3x |   0.0002799         |   0.0002798         | 0.0005682    
     downstream 10x|   0.0002808         |   0.0002807         | 0.0005700    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   1.82049880e-04 
       upstream 3x |   -1.79888470e-04 
       upstream 10x|   -1.77525300e-04 
      downstream   |   0.00000000e+00 
     downstream 3x |   -1.78667140e-04 
     downstream 10x|   -1.78094390e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 926 at Thu Aug 12 15:46:58 EDT 1999
    Electron Q1 power supply current        : 444.85
    Electron Q1 momentum                    : 0.594547
    Electron Q1 gauss meter                 : -0.03773
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 254.702
    Electron Q2 momentum                    : 0.594758
    Electron Q2 gauss meter                 : 0.1337
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 197.565
    Electron D1 momentum                    : 0.594989
    Electron D1 NMR                         : 0.21918
    Electron Q3 power supply current        : 235.604
    Electron Q3 momentum                    : 0.595048
    Electron Q3 gauss meter                 : -0.11577
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 361.97
    Hadron Q1 momentum                      : 0.484032
    Hadron Q1 gauss meter                   : 0.009275
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 206.998
    Hadron Q2 momentum                      : 0.483626
    Hadron Q2 gauss meter                   : -0.10879
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 166.647
    Hadron D1 momentum                      : 0.483999
    Hadron D1 NMR                           : 0.178624
    Hadron Q3 power supply current          : 191.657
    Hadron Q3 momentum                      : 0.48431
    Hadron Q3 gauss meter                   : -0.08577
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 2.56703
    Current on Unser monitor                : -3.72324
    Current on Upstream bcm                 : 2.56971
    Current on Downstream bcm               : 2.56436
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 856.606