• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:52:18 on August 18, 1999

    Entry number 25545

    keyword=End_of_Run_1232
    ****************************
     Run Number: 1232
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Pmom=1.251,Rad=0,Ene=1.669,Angle_e=48.558,Angle_h=38.61
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  746.83094  Hz     |    760.34025 Hz   |  753.2396 Hz
        2      |  94.127122  Hz     |    93.024923 Hz   |  93.616627 Hz
        3      |  3076.945  Hz     |    3120.7474 Hz   |  3098.4508 Hz
        4      |  13863.55  Hz     |    13891.505 Hz   |  13874.894 Hz
        5      |  467.73352  Hz     |    479.41263 Hz   |  473.52749 Hz
        output |  2528.1247  Hz   |    2552.3976 Hz |  2540.0609 Hz
     Total number of output triggers =     2.70132e+05 
     Number of raw T1 80106.0  ; Number of raw T3 329516.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 1.7724772 min
     Time of run h- = 0.87252603 min
     Time of run h+ = 0.87293295 min
     1-(sum of time hel + and -)/( run time) = 1.5243e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5036228  Hz         |    0.0 Hz        |  15.007246 Hz
          -        |  0.0  Hz        |    15.007246 Hz       |  15.007246 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0012943         |   0.0012933         | 0.0026268     
       upstream 3x |   0.0012988         |   0.0012978         | 0.0026358     
       upstream 10x|   0.0013055         |   0.0013045         | 0.0026495     
      downstream   |   0.0012939         |   0.0012928         | 0.0026258    
     downstream 3x |   0.0012995         |   0.0012985         | 0.0026374    
     downstream 10x|   0.0013011         |   0.0013001         | 0.0026406    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -3.86458490e-04 
       upstream 3x |   -3.85119000e-04 
       upstream 10x|   -3.83141760e-04 
      downstream   |   -4.25252250e-04 
     downstream 3x |   -3.84911470e-04 
     downstream 10x|   -3.84437950e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1232 at Wed Aug 18 19:52:17 EDT 1999
    Electron Q1 power supply current        : 779.38
    Electron Q1 momentum                    : 1.04165
    Electron Q1 gauss meter                 : -0.06602
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 446.248
    Electron Q2 momentum                    : 1.04204
    Electron Q2 gauss meter                 : 0.2348
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 346.389
    Electron D1 momentum                    : 1.042
    Electron D1 NMR                         : 0.383662
    Electron Q3 power supply current        : 412.699
    Electron Q3 momentum                    : 1.04233
    Electron Q3 gauss meter                 : -0.20461
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 935.55
    Hadron Q1 momentum                      : 1.25103
    Hadron Q1 gauss meter                   : 0.023666
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 535.338
    Hadron Q2 momentum                      : 1.25075
    Hadron Q2 gauss meter                   : -0.2812
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 427.14
    Hadron D1 momentum                      : 1.251
    Hadron D1 NMR                           : 0.461692
    Hadron Q3 power supply current          : 495.08
    Hadron Q3 momentum                      : 1.25105
    Hadron Q3 gauss meter                   : -0.22159
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 25.0424
    Current on Unser monitor                : 18.4762
    Current on Upstream bcm                 : 25.0789
    Current on Downstream bcm               : 25.006
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1668.8