• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 02:39:30 on August 19, 1999

    Entry number 25598

    keyword=End_of_Run_1253
    ****************************
     Run Number: 1253
    End of Run Comment:
    Tar=LH2-15cm,Type=Inelastic,Pmom=1.637,Rad=6,Ene=1.669,Angle_e=79.043,Angle_h=23.935
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  24.568279  Hz     |    26.920048 Hz   |  25.747463 Hz
        2      |  98.258491  Hz     |    98.234046 Hz   |  98.11404 Hz
        3      |  1990.0306  Hz     |    1993.9698 Hz   |  1991.8886 Hz
        4      |  22596.016  Hz     |    22564.556 Hz   |  22583.442 Hz
        5      |  8.2625461  Hz     |    9.4461438 Hz   |  8.8297594 Hz
        output |  0.014623975  Hz   |    0.0 Hz |  0.0072020876 Hz
     Total number of output triggers =     1.00000e+00 
     Number of raw T1 3575.0  ; Number of raw T3 276571.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 2.3141438 min
     Time of run h- = 1.1397949 min
     Time of run h+ = 1.139681 min
     1-(sum of time hel + and -)/( run time) = 1.4981e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5045753  Hz         |    0.0 Hz        |  15.009151 Hz
          -        |  0.0  Hz        |    15.001949 Hz       |  15.009151 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0005552         |   0.0005545         | 0.0011263     
       upstream 3x |   0.0005582         |   0.0005575         | 0.0011325     
       upstream 10x|   0.0005622         |   0.0005614         | 0.0011405     
      downstream   |   0.0005555         |   0.0005547         | 0.0011270    
     downstream 3x |   0.0005595         |   0.0005587         | 0.0011351    
     downstream 10x|   0.0005605         |   0.0005597         | 0.0011371    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -6.30801120e-04 
       upstream 3x |   -6.27408800e-04 
       upstream 10x|   -7.11997150e-04 
      downstream   |   -7.20590880e-04 
     downstream 3x |   -7.15435520e-04 
     downstream 10x|   -7.14158190e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1253 at Thu Aug 19 02:39:24 EDT 1999
    Electron Q1 power supply current        : 505.575
    Electron Q1 momentum                    : 0.675707
    Electron Q1 gauss meter                 : -0.04289
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 289.53
    Electron Q2 momentum                    : 0.676087
    Electron Q2 gauss meter                 : 0.15249
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 223.957
    Electron D1 momentum                    : 0.675989
    Electron D1 NMR                         : 0.248985
    Electron Q3 power supply current        : 267.67
    Electron Q3 momentum                    : 0.676034
    Electron Q3 gauss meter                 : -0.13224
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 1224.09
    Hadron Q1 momentum                      : 1.63687
    Hadron Q1 gauss meter                   : 0.03085
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 700.697
    Hadron Q2 momentum                      : 1.63709
    Hadron Q2 gauss meter                   : -0.368
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 560.866
    Hadron D1 momentum                      : 1.637
    Hadron D1 NMR                           : 0.604148
    Hadron Q3 power supply current          : 647.95
    Hadron Q3 momentum                      : 1.63735
    Hadron Q3 gauss meter                   : -0.2901
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 8.23652
    Current on Unser monitor                : 1.73282
    Current on Upstream bcm                 : 8.24562
    Current on Downstream bcm               : 8.22742
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1668.8