• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 10:36:25 on August 27, 1999

    Entry number 26321

    keyword=End_of_Run_1500
    ****************************
     Run Number: 1500
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Pmom=1.133,Rad=0,Ene=1.667,Angle_e=42.652,Angle_h=42.685
    increase current from 20 microamps to 22 microamps
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  2556.0758  Hz     |    2550.4745 Hz   |  2553.4368 Hz
        2      |  116.90558  Hz     |    116.62327 Hz   |  116.86451 Hz
        3      |  5469.3382  Hz     |    5465.2016 Hz   |  5468.1625 Hz
        4      |  13057.318  Hz     |    13036.387 Hz   |  13050.034 Hz
        5      |  2158.0318  Hz     |    2154.3945 Hz   |  2156.3803 Hz
        output |  1741.9498  Hz   |    1742.1448 Hz |  1742.1982 Hz
     Total number of output triggers =     1.50642e+06 
     Number of raw T1 2207875.0  ; Number of raw T3 4728145.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 14.411133 min
     Time of run h- = 7.09764 min
     Time of run h+ = 7.0970378 min
     1-(sum of time hel + and -)/( run time) = 1.5020e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.4988322  Hz         |    0.0 Hz        |  14.998821 Hz
          -        |  0.0  Hz        |    14.998821 Hz       |  14.998821 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0086347         |   0.0086237         | 0.0175237     
       upstream 3x |   0.0086664         |   0.0086556         | 0.0175885     
       upstream 10x|   0.0087137         |   0.0087026         | 0.0176843     
      downstream   |   0.0086349         |   0.0086240         | 0.0175243    
     downstream 3x |   0.0086761         |   0.0086655         | 0.0176082    
     downstream 10x|   0.0086874         |   0.0086765         | 0.0176309    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -6.37370790e-04 
       upstream 3x |   -6.23484590e-04 
       upstream 10x|   -6.37333990e-04 
      downstream   |   -6.31558210e-04 
     downstream 3x |   -6.11246940e-04 
     downstream 10x|   -6.27739160e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1500 at Fri Aug 27 10:35:48 EDT 1999
    Electron Q1 power supply current        : 848.4
    Electron Q1 momentum                    : 1.1339
    Electron Q1 gauss meter                 : -0.07189
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 485.782
    Electron Q2 momentum                    : 1.13436
    Electron Q2 gauss meter                 : 0.25614
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 376.775
    Electron D1 momentum                    : 1.134
    Electron D1 NMR                         : 0.417518
    Electron Q3 power supply current        : 449.036
    Electron Q3 momentum                    : 1.1341
    Electron Q3 gauss meter                 : -0.22352
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 847.315
    Hadron Q1 momentum                      : 1.13304
    Hadron Q1 gauss meter                   : 0.0215
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 484.919
    Hadron Q2 momentum                      : 1.13295
    Hadron Q2 gauss meter                   : -0.2557
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 384.564
    Hadron D1 momentum                      : 1.133
    Hadron D1 NMR                           : 0.418143
    Hadron Q3 power supply current          : 448.475
    Hadron Q3 momentum                      : 1.13328
    Hadron Q3 gauss meter                   : -0.2014
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 22.1988
    Current on Unser monitor                : 16.1869
    Current on Upstream bcm                 : 22.1899
    Current on Downstream bcm               : 22.2078
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1669.15