• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name gilman

    Log entry time 16:15:09 on September 22,1999

    Entry number 26947

    keyword=9-22 day shift summary

    7:53 - 8:54: run 1737, last e + d run, 164 k, 107 k T3

    8:55 tune beam for 10 minutes

    9:10 let Saha do "5 minute" HARP scan check for 15 minutes

    9:25 put target back in

    9:35 not enough current, 10 minutes beam tuning

    9:50, start e+p run 1739 with 11 microA current, stopped 11:00 @ 81 k, 38l T3

    11:00 start run 1740, 11 micro A drops to 10 at ~11:30

    11:18 Zone drop out beam off couple minutes

    11:50: Stop run 1740, 24 of 47 k events are T3s.
    Put in radiator and open carbon doors.

    11:55 Start run 1741 as check of garbage with no fpp doors in, gamma+p.
    Doors open last 1/3 of way / 45 s / first 4.4 k of run.
    Take 26 k total events in 6 minutes.

    12:00 waiting for access, asked for ep setup to be started during this.
    12:30 access complete
    13:00 e-p starts
    13:45 e-p ends.
    13:45 access to BSY . also access to hall to go to 13.5
    14:45 Put a little cesium on wafer. May increase current.


    more accessers and waiting for beam, no C(e,e') at end of shift