User name apar

Log entry time 19:35:09 on June 20, 2019

Entry number 444954

keyword=Start_Parity_Run_2741,CODA_Config=ALL_PREX,Run_type=Test,beam_current=2,beam_energy=0.95,beam_raster=off,parity_feedback=off,parity_ihwp=out,target_type=Home
Beginning-of-Parity-run EPICS data for Run Number 2741 at Thu Jun 20 19:34:33 EDT 2019
CODA Configuration: ALL_PREX

Comment: excersing the parity DAQ with low current

# Timing board information: # Integrate Time = 0.88 ms, Ramp Delay = 100.00 us oversamp 1

Polarized Beam Info : 0
-----------------------------------------
Wien angle (Vertical) : 88.0008
Wien Vertical BDL (Gcm) : 2632.1
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 89.0458
Wien BDL (First Solenoid) (Gcm) : 964.5
Wien BDL (Second Solenoid) (Gcm) : 1012.1
Wien angle (Horizontal) : -15.5
Wien BDL (Gcm) : -461.53
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 140.014
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1531.97
RTP ON/OFF : ON
RTP voltage 1 : 14550
RTP voltage 2 : 11532
RTP voltage 3 : 13378
RTP voltage 4 : 12704
RTP voltage 5 : 13808
RTP voltage 6 : 10790
RTP voltage 7 : 12636
RTP voltage 8 : 11962
RTP QTR wave V L/4 : 12670
RTP QTR wave V L/4,1 : 12670
RTP QTR wave V L/4,2 : 12670
RTP PITA : 371
RTP PITA,1 : 371
RTP PITA,2 : 371
RTP Alpha Pos U : 1509
RTP Alpha Pos V : 337
RTP Delta Pos U : 0
RTP Delta Pos V : 0
Hall A IA V1 : 42570
Hall A IA V2 : 42570
Hall A IA V3 : 42570
Hall A IA V4 : 42570
Hall B IA V1 : 37286
Hall B IA V2 : 37286
Hall B IA V3 : 37286
Hall B IA V4 : 37286
Hall C IA V1 : 25881
Hall C IA V2 : 25881
Hall C IA V3 : 25881
Hall C IA V4 : 25881
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : 0
Pockels Cell Y Stage : 0
Wager X Stage : 13250
Wager Y Stage : 10500
Hall A Slit Position : -0.994629
Helicity Clock Set : 120 Hz LineSync
Helicity Clock Read : 120 Hz LineSync
Helicity Delay Set : 8 windows
Helicity Delay Read : 8 windows
Helicity Settle Read : 90
Helicity Stable Read : 8243.33
Helicity Pattern Set : Quartet
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 42mW
Calculated power in cavity : 0.0106968
Photodiode on table : 0
Laser X position on QPD 1 : -221.828
Laser Y position on QPD 1 : 11601.3
Laser X position on QPD 2 : 438.596
Laser Y position on QPD 2 : 737.463
QPD 1 sum : 0.00244156
QPD 2 sum : 0.00366233
Position set point for adjustable
mirror 1 (either x or y) : -10110[c]
Position set point for adjustable
mirror 2 (either x or y) : -8021[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.200
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0433376
Gain of locking servo : 138
Tracking level (V) of locking servo : 1.1
Slow locking signal sent to laser : 0.12635
Fast locking signal sent to laser : -3.95349
Calculated polarisation in cavity : 0
Photodiode 1 after Wollaston prism : 0.00116684
Photodiode 2 after Wollaston prism : 0.000381616
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 132.093
Left Arm Q1 momentum : 0.632961
Left Arm Q1 gauss meter : -0.2168
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 412.767
Left Arm Q2 momentum : 0.950073
Left Arm Q2 gauss meter : 0.2173
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 315.298
Left Arm D1 momentum : 0.950004
Left Arm D1 NMR : 0.351733
Left Arm Q3 power supply current : 509.27
Left Arm Q3 momentum : 0.949815
Left Arm Q3 gauss meter : -0.25688
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 132.229
Right Arm Q1 momentum : 0.660158
Right Arm Q1 gauss meter : -0.19141
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 414.216
Right Arm Q2 momentum : 0.949952
Right Arm Q2 gauss meter : 0.2165
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 326.684
Right Arm D1 momentum : 0.949992
Right Arm D1 NMR : 0.352531
Right Arm Q3 power supply current : 512.638
Right Arm Q3 momentum : 0.950139
Right Arm Q3 gauss meter : 0.2287
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 69.043
Left Arm Bottom VDC Current : 20.4102
Right Arm Top VDC Current : -5.9082
Right Arm Bottom VDC Current : -5.27344
Left Arm Top VDC voltage : 0.389648
Left Arm Bottom VDC voltage : 0.840332
Right Arm Top VDC voltage : -0.0410156
Right Arm Bottom VDC voltage : -0.0541992
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 2.15662
Current on Unser monitor : 6.69928
Current on Upstream bcm : 2.15786
Current on Downstream bcm : 2.15538
Upstream Cavity Coefficient : 38.6
Downstream Cavity Coefficient : 39.8
Current on IBC0L02 (source) : 1.7881
Hall B current : 31.239
Hall C current : 0
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
dp/p : 0.000108231
MBSY1c Hall A Beam energy : 1.63185e+06
MBSY3c Hall C Beam energy : -4.7699e+06
MBSY1c magnet current (amp) : 39.2847
MBSY1c Bdl : 237276
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : relative
RF gain high/low : High
Gain mode: manual, automatic : automatic
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster Height : 6
Raster Width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -1.50715
IPM1C12.YPOS : 0.309467
IPM1H04A.XPOS : -0.0236187
IPM1H04A.YPOS : 0.00611691
IPM1H04E.XPOS : -0.14644
IPM1H04E.YPOS : -1.13247
Survey X offset bpm4A : 0
Survey Y offset bpm4A : 0
Survey X offset bpm4B : 0
Survey Y offset bpm4B : 0
Survey X offset bpm12 : -1.52228
Survey Y offset bpm12 : 0.31184
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Moeller Magnet Currents
-----------------------------------------
Moeller ON/OFF : disabled
MQO1H02 Setpoint(Amps) : 21.1926
MQO1H02 Readback(Amps) : 20.3883
MQM1H02 Setpoint(Amps) : -18.7778
MQM1H02 Readback(Amps) : -18.696
MQO1H03 Setpoint(Amps) : 18.2412
MQO1H03 Readback(Amps) : 18.276
MQO1H03A Setpoint(Amps) : 18.381
MQO1H03A Readback(Amps) : 18.4542
MMA1H01 Setpoint(Amps) : 100
MMA1H01 Readback(Amps) : 0.0381476