User name apar
Log entry time 01:20:52 on June 20, 2019
Entry number 444907
keyword=End_of_Parity_Run_2734
Run Number: 2734
End of Run Comment:
Run_type=Test,beam_current=0,beam_energy=0.000,beam_raster=off,comment_text=Reduced all HAPTB integrate gates by 3 ticks, to try to avoid the beamsync jitter more,parity_feedback=off,parity_ihwp=out,target_fanspeed=0 Hz,target_type=Home
End-of-Parity-run EPICS data for Run Number 2734 at Thu Jun 20 01:20:41 EDT 2019
CODA Configuration: ALL_PREX
# Timing board information: # Integrate Time = 0.88 ms, Ramp Delay = 100.00 us oversamp 1
Total Events:
-----------------------------------------
Polarized Beam Info : 0
-----------------------------------------
Wien angle (Vertical) : 88.0008
Wien Vertical BDL (Gcm) : 2632.1
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 89.0458
Wien BDL (First Solenoid) (Gcm) : 964.5
Wien BDL (Second Solenoid) (Gcm) : 1012.1
Wien angle (Horizontal) : -15.5
Wien BDL (Gcm) : -461.53
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 170.002
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1531.97
RTP ON/OFF : ON
RTP voltage 1 : 14550
RTP voltage 2 : 11532
RTP voltage 3 : 13378
RTP voltage 4 : 12704
RTP voltage 5 : 13808
RTP voltage 6 : 10790
RTP voltage 7 : 12636
RTP voltage 8 : 11962
RTP QTR wave V L/4 : 12670
RTP QTR wave V L/4,1 : 12670
RTP QTR wave V L/4,2 : 12670
RTP PITA : 371
RTP PITA,1 : 371
RTP PITA,2 : 371
RTP Alpha Pos U : 1509
RTP Alpha Pos V : 337
RTP Delta Pos U : 0
RTP Delta Pos V : 0
Hall A IA V1 : 42570
Hall A IA V2 : 42570
Hall A IA V3 : 42570
Hall A IA V4 : 42570
Hall B IA V1 : 37286
Hall B IA V2 : 37286
Hall B IA V3 : 37286
Hall B IA V4 : 37286
Hall C IA V1 : 25881
Hall C IA V2 : 25881
Hall C IA V3 : 25881
Hall C IA V4 : 25881
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : 0
Pockels Cell Y Stage : 0
Wager X Stage : 13250
Wager Y Stage : 10500
Hall A Slit Position : -0.992676
Helicity Clock Set : 120 Hz LineSync
Helicity Clock Read : 120 Hz LineSync
Helicity Delay Set : 8 windows
Helicity Delay Read : 8 windows
Helicity Settle Read : 90
Helicity Stable Read : 8243.33
Helicity Pattern Set : Quartet
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 30mW
Calculated power in cavity : 0.0165834
Photodiode on table : 0
Laser X position on QPD 1 : -221.828
Laser Y position on QPD 1 : 10294.1
Laser X position on QPD 2 : 263.158
Laser Y position on QPD 2 : 553.097
QPD 1 sum : 0.00244156
QPD 2 sum : 0.00610389
Position set point for adjustable
mirror 1 (either x or y) : -10060[c]
Position set point for adjustable
mirror 2 (either x or y) : -7971[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.183
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0445584
Gain of locking servo : 141
Tracking level (V) of locking servo : 1.1
Slow locking signal sent to laser : 0.12635
Fast locking signal sent to laser : -4.52115
Calculated polarisation in cavity : 0
Photodiode 1 after Wollaston prism : 0.00110227
Photodiode 2 after Wollaston prism : 0.00129832
Step size for RHWP scan : 2500
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 49.9687
Left Arm Q1 momentum : 0.239851
Left Arm Q1 gauss meter : -0.07792
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.0249225
Left Arm Q2 momentum : 0.00479789
Left Arm Q2 gauss meter : 0.0012428
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -2.0376
Left Arm D1 momentum : 0.00270467
Left Arm D1 NMR : 0.428101
Left Arm Q3 power supply current : 0.78982
Left Arm Q3 momentum : 0.00715576
Left Arm Q3 gauss meter : -0.00063193
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 0.00699
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.00202149
Right Arm Q2 momentum : -2.28001e-06
Right Arm Q2 gauss meter : 0.0002826
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 12.0046
Right Arm D1 momentum : 0.0271959
Right Arm D1 NMR : 0.282866
Right Arm Q3 power supply current : 0.0682324
Right Arm Q3 momentum : 0.0034227
Right Arm Q3 gauss meter : 0.0003119
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 68.7988
Left Arm Bottom VDC Current : 21.4355
Right Arm Top VDC Current : -3.22266
Right Arm Bottom VDC Current : -5.27344
Left Arm Top VDC voltage : 0.396484
Left Arm Bottom VDC voltage : 0.837891
Right Arm Top VDC voltage : -0.0664062
Right Arm Bottom VDC voltage : -0.0556641
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 1.21241
Current on Unser monitor : 5.14479
Current on Upstream bcm : 1.21912
Current on Downstream bcm : 1.2028
Upstream Cavity Coefficient : 38.6
Downstream Cavity Coefficient : 39.8
Current on IBC0L02 (source) : 0.592027
Hall B current : 27.69
Hall C current : 0
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
dp/p : 0.000174656
MBSY1c Hall A Beam energy : 1.63116e+06
MBSY3c Hall C Beam energy : -4.7699e+06
MBSY1c magnet current (amp) : 39.2678
MBSY1c Bdl : 237176
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : relative
RF gain high/low : High
Gain mode: manual, automatic : automatic
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -2.06501
IPM1C12.YPOS : 0.775006
IPM1H04A.XPOS : -0.0155173
IPM1H04A.YPOS : 1.63724
IPM1H04E.XPOS : 0.0947755
IPM1H04E.YPOS : -0.0405292
Survey X offset bpm4A : 0
Survey Y offset bpm4A : 0
Survey X offset bpm4B : 0
Survey Y offset bpm4B : 0
Survey X offset bpm12 : -2.04547
Survey Y offset bpm12 : 0.764977
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Moeller Magnet Currents
-----------------------------------------
Moeller ON/OFF : disabled
MQO1H02 Setpoint(Amps) : 21.1926
MQO1H02 Readback(Amps) : 19.7436
MQM1H02 Setpoint(Amps) : -18.7778
MQM1H02 Readback(Amps) : -17.4872
MQO1H03 Setpoint(Amps) : 18.2412
MQO1H03 Readback(Amps) : 18.2719
MQO1H03A Setpoint(Amps) : 18.381
MQO1H03A Readback(Amps) : 16.7619
MMA1H01 Setpoint(Amps) : 100
MMA1H01 Readback(Amps) : 0.0381476
----------------------------------------
Beamline Element Temperatures
----------------------------------------
Upstream part of W Collimator : 4.71826
Downstream part of W Collimator : 4.85596
Sieve Box : 5.05664
Beamline : 4.78027