User name apar

Log entry time 10:01:13 on June 25, 2019

Entry number 667

keyword=Start_Parity_Run_2844,CODA_Config=ALL_PREX,Run_type=Test,beam_current=0,beam_energy=0.95,beam_raster=off,parity_feedback=off,parity_ihwp=out,target_type=Home
Beginning-of-Parity-run EPICS data for Run Number 2844 at Tue Jun 25 10:00:40 EDT 2019
CODA Configuration: ALL_PREX

Comment: Running Parity DAQ just because

# Timing board information: # Integrate Time = 0.88 ms, Ramp Delay = 100.00 us oversamp 1

Polarized Beam Info : 0
-----------------------------------------
Wien angle (Vertical) : 88.0008
Wien Vertical BDL (Gcm) : 2632.1
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 89.0458
Wien BDL (First Solenoid) (Gcm) : 964.5
Wien BDL (Second Solenoid) (Gcm) : 1012.1
Wien angle (Horizontal) : -15.5
Wien BDL (Gcm) : -461.53
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 180.05
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1531.97
RTP ON/OFF : ON
RTP voltage 1 : 14550
RTP voltage 2 : 11532
RTP voltage 3 : 13378
RTP voltage 4 : 12704
RTP voltage 5 : 13808
RTP voltage 6 : 10790
RTP voltage 7 : 12636
RTP voltage 8 : 11962
RTP QTR wave V L/4 : 12670
RTP QTR wave V L/4,1 : 12670
RTP QTR wave V L/4,2 : 12670
RTP PITA : 371
RTP PITA,1 : 371
RTP PITA,2 : 371
RTP Alpha Pos U : 1509
RTP Alpha Pos V : 337
RTP Delta Pos U : 0
RTP Delta Pos V : 0
Hall A IA V1 : 42570
Hall A IA V2 : 42570
Hall A IA V3 : 42570
Hall A IA V4 : 42570
Hall B IA V1 : 37286
Hall B IA V2 : 37286
Hall B IA V3 : 37286
Hall B IA V4 : 37286
Hall C IA V1 : 25881
Hall C IA V2 : 25881
Hall C IA V3 : 25881
Hall C IA V4 : 25881
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : 0
Pockels Cell Y Stage : 0
Wager X Stage : 13250
Wager Y Stage : 10500
Hall A Slit Position : -0.994141
Helicity Clock Set : 120 Hz LineSync
Helicity Clock Read : 120 Hz LineSync
Helicity Delay Set : 8 windows
Helicity Delay Read : 8 windows
Helicity Settle Read : 90
Helicity Stable Read : 8243.33
Helicity Pattern Set : Quartet
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 42mW
Calculated power in cavity : 0.00889436
Photodiode on table : 0
Laser X position on QPD 1 : -665.484
Laser Y position on QPD 1 : 6427.02
Laser X position on QPD 2 : 328.947
Laser Y position on QPD 2 : 553.097
QPD 1 sum : 0.00244156
QPD 2 sum : 0.00488311
Position set point for adjustable
mirror 1 (either x or y) : -10110[c]
Position set point for adjustable
mirror 2 (either x or y) : -7971[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.245
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0445584
Gain of locking servo : 137
Tracking level (V) of locking servo : 1.1
Slow locking signal sent to laser : 0.130013
Fast locking signal sent to laser : 0.961362
Calculated polarisation in cavity : 0
Photodiode 1 after Wollaston prism : 0.00108843
Photodiode 2 after Wollaston prism : 0.000199104
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1.96384
Left Arm Q1 momentum : 0.00940143
Left Arm Q1 gauss meter : 0.00373
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.0252257
Left Arm Q2 momentum : 0.00492984
Left Arm Q2 gauss meter : 0.0012728
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.91325
Left Arm D1 momentum : 0.00447652
Left Arm D1 NMR : 0.225898
Left Arm Q3 power supply current : 0.78928
Left Arm Q3 momentum : 0.0066489
Left Arm Q3 gauss meter : -0.00063767
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1.90661
Right Arm Q1 momentum : 0.00961092
Right Arm Q1 gauss meter : 0.00389
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.00200676
Right Arm Q2 momentum : -4.60224e-06
Right Arm Q2 gauss meter : 0.0003234
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 3.58214
Right Arm D1 momentum : 0.0319516
Right Arm D1 NMR : 0.235786
Right Arm Q3 power supply current : 0.0672049
Right Arm Q3 momentum : 0.00349659
Right Arm Q3 gauss meter : 0.0003247
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 69.3359
Left Arm Bottom VDC Current : 20.9473
Right Arm Top VDC Current : -6.10352
Right Arm Bottom VDC Current : -5.12695
Left Arm Top VDC voltage : 0.387695
Left Arm Bottom VDC voltage : 0.839355
Right Arm Top VDC voltage : -0.0395508
Right Arm Bottom VDC voltage : -0.0546875
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 0.0539481
Current on Unser monitor : 5.41812
Current on Upstream bcm : 0.0575744
Current on Downstream bcm : 0.0503218
Upstream Cavity Coefficient : 38.6
Downstream Cavity Coefficient : 39.8
Current on IBC0L02 (source) : 0.712511
Hall B current : 0.30771
Hall C current : 0
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
dp/p : 0
MBSY1c Hall A Beam energy : 1.63185e+06
MBSY3c Hall C Beam energy : -4.7699e+06
MBSY1c magnet current (amp) : 4
MBSY1c Bdl : 237276
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : relative
RF gain high/low : High
Gain mode: manual, automatic : automatic
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster Height : 0.2
Raster Width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04E.XPOS : 0.130578
IPM1H04E.YPOS : 1.96878
Survey X offset bpm4A : 0
Survey Y offset bpm4A : 0
Survey X offset bpm4B : 0
Survey Y offset bpm4B : 0
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Moeller Magnet Currents
-----------------------------------------
Moeller ON/OFF : disabled
MQO1H02 Setpoint(Amps) : 21.1926
MQO1H02 Readback(Amps) : 20.3883
MQM1H02 Setpoint(Amps) : -18.7778
MQM1H02 Readback(Amps) : -16.9231
MQO1H03 Setpoint(Amps) : 18.2412
MQO1H03 Readback(Amps) : 18.2802
MQO1H03A Setpoint(Amps) : 18.381
MQO1H03A Readback(Amps) : 17.4872
MMA1H01 Setpoint(Amps) : 100
MMA1H01 Readback(Amps) : 0.0381476