User name apar

Log entry time 00:45:43 on July 13, 2019

Entry number 2344

keyword=End_of_Parity_Run_3215
Run Number: 3215
End of Run Comment:
Run_type=Junk,beam_current=0,beam_energy=0.95,beam_raster=on,comment_text=Junk, no beam,parity_feedback=off,parity_ihwp=out,target_type=Home Event Rate is low (0-1), reopen CODA
End-of-Parity-run EPICS data for Run Number 3215 at Sat Jul 13 00:45:25 EDT 2019
CODA Configuration: ALL_PREX

# Timing board information: # Integrate Time = 0.88 ms, Ramp Delay = 100.00 us oversamp 1

Total Events: 0
-----------------------------------------
Polarized Beam Info : 0
-----------------------------------------
Wien angle (Vertical) : 88.0008
Wien Vertical BDL (Gcm) : 2632.1
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 91.1902
Wien BDL (First Solenoid) (Gcm) : 1012.1
Wien BDL (Second Solenoid) (Gcm) : 1012.1
Wien angle (Horizontal) : -15.5
Wien BDL (Gcm) : -461.53
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 100.17
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1.001
RTP ON/OFF : ON
RTP voltage 1 : 14550
RTP voltage 2 : 11532
RTP voltage 3 : 13378
RTP voltage 4 : 12704
RTP voltage 5 : 13808
RTP voltage 6 : 10790
RTP voltage 7 : 12636
RTP voltage 8 : 11962
RTP QTR wave V L/4 : 12670
RTP QTR wave V L/4,1 : 12670
RTP QTR wave V L/4,2 : 12670
RTP PITA : 371
RTP PITA,1 : 371
RTP PITA,2 : 371
RTP Alpha Pos U : 1509
RTP Alpha Pos V : 337
RTP Delta Pos U : 0
RTP Delta Pos V : 0
Hall A IA V1 : 42570
Hall A IA V2 : 42570
Hall A IA V3 : 42570
Hall A IA V4 : 42570
Hall B IA V1 : 37286
Hall B IA V2 : 37286
Hall B IA V3 : 37286
Hall B IA V4 : 37286
Hall C IA V1 : 25881
Hall C IA V2 : 25881
Hall C IA V3 : 25881
Hall C IA V4 : 25881
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : 0
Pockels Cell Y Stage : 0
Wager X Stage : 13250
Wager Y Stage : 10500
Hall A Slit Position : -1.00146
Helicity Clock Set : Free Clock
Helicity Clock Read : Free Clock
Helicity Delay Set : 8 windows
Helicity Delay Read : 8 windows
Helicity Settle Read : 90
Helicity Stable Read : 8243.35
Helicity Pattern Set : Quartet
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 36mW
Calculated power in cavity : 0.0210813
Photodiode on table : 0
Laser X position on QPD 1 : -1.95134e+15
Laser Y position on QPD 1 : -326.797
Laser X position on QPD 2 : 109.649
Laser Y position on QPD 2 : 553.097
QPD 1 sum : -2.77556e-16
QPD 2 sum : 0.00488311
Position set point for adjustable
mirror 1 (either x or y) : -1100[c]
Position set point for adjustable
mirror 2 (either x or y) : 14300[c]
Laser minimum temperature (35.8) : 31.8
Laser temperature set point : +46.844
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0433376
Gain of locking servo : 165
Tracking level (V) of locking servo : 0.55
Slow locking signal sent to laser : 0.122688
Fast locking signal sent to laser : -6.07032
Calculated polarisation in cavity : 0
Photodiode 1 after Wollaston prism : 0.00160959
Photodiode 2 after Wollaston prism : 0.00116144
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 118.445
Left Arm Q1 momentum : 0.567346
Left Arm Q1 gauss meter : -0.19426
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 404.846
Left Arm Q2 momentum : 0.931838
Left Arm Q2 gauss meter : 0.2132
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 316.178
Left Arm D1 momentum : 0.952868
Left Arm D1 NMR : 0.352793
Left Arm Q3 power supply current : 450.965
Left Arm Q3 momentum : 0.841073
Left Arm Q3 gauss meter : -0.22752
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 118.482
Right Arm Q1 momentum : 0.591322
Right Arm Q1 gauss meter : -0.17129
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 403.61
Right Arm Q2 momentum : 0.925626
Right Arm Q2 gauss meter : 0.211
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 327.422
Right Arm D1 momentum : 0.952864
Right Arm D1 NMR : 0.353596
Right Arm Q3 power supply current : 445.414
Right Arm Q3 momentum : 0.825543
Right Arm Q3 gauss meter : 0.19923
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 69.0918
Left Arm Bottom VDC Current : 20.5078
Right Arm Top VDC Current : -6.10352
Right Arm Bottom VDC Current : -5.22461
Left Arm Top VDC voltage : 0.389648
Left Arm Bottom VDC voltage : 0.834473
Right Arm Top VDC voltage : -0.0644531
Right Arm Bottom VDC voltage : -0.0512695
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 0.0306924
Current on Unser monitor : 5.04689
Current on Upstream bcm : 0.00865026
Current on Downstream bcm : 0.0527345
Upstream Cavity Coefficient : 38.6
Downstream Cavity Coefficient : 39.8
Current on IBC0L02 (source) : 0.825336
Hall B current : 0.27183
Hall C current : 0
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
dp/p : 0
MBSY1c Hall A Beam energy : 1.63226e+06
MBSY3c Hall C Beam energy : -6.2812e+06
MBSY1c magnet current (amp) : 4
MBSY1c Bdl : 237336
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 1