Log entry time 05:14:34 on June 23, 2019
Entry number 222
keyword=End_of_Parity_Run_2809
Run Number: 2809
End of Run Comment:
Run_type=Calibration,beam_current=0.03,beam_energy=0.95,beam_raster=on,comment_text=running with intermittent low current (~0.03 uA),parity_feedback=off,parity_ihwp=out,target_type=Carbon 0.25%
*beam modulation test
End-of-Parity-run EPICS data for Run Number 2809 at Sun Jun 23 05:14:22 EDT 2019
CODA Configuration: ALL_PREX
# Timing board information: # Integrate Time = 0.88 ms, Ramp Delay = 100.00 us oversamp 1
Total Events:
-----------------------------------------
Polarized Beam Info : 0
-----------------------------------------
Wien angle (Vertical) : 88.0008
Wien Vertical BDL (Gcm) : 2632.1
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 89.0458
Wien BDL (First Solenoid) (Gcm) : 964.5
Wien BDL (Second Solenoid) (Gcm) : 1012.1
Wien angle (Horizontal) : -15.5
Wien BDL (Gcm) : -461.53
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 130.055
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1531.97
RTP ON/OFF : ON
RTP voltage 1 : 14550
RTP voltage 2 : 11532
RTP voltage 3 : 13378
RTP voltage 4 : 12704
RTP voltage 5 : 13808
RTP voltage 6 : 10790
RTP voltage 7 : 12636
RTP voltage 8 : 11962
RTP QTR wave V L/4 : 12670
RTP QTR wave V L/4,1 : 12670
RTP QTR wave V L/4,2 : 12670
RTP PITA : 371
RTP PITA,1 : 371
RTP PITA,2 : 371
RTP Alpha Pos U : 1509
RTP Alpha Pos V : 337
RTP Delta Pos U : 0
RTP Delta Pos V : 0
Hall A IA V1 : 42570
Hall A IA V2 : 42570
Hall A IA V3 : 42570
Hall A IA V4 : 42570
Hall B IA V1 : 37286
Hall B IA V2 : 37286
Hall B IA V3 : 37286
Hall B IA V4 : 37286
Hall C IA V1 : 25881
Hall C IA V2 : 25881
Hall C IA V3 : 25881
Hall C IA V4 : 25881
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : 0
Pockels Cell Y Stage : 0
Wager X Stage : 13250
Wager Y Stage : 10500
Hall A Slit Position : -0.997559
Helicity Clock Set : 120 Hz LineSync
Helicity Clock Read : 120 Hz LineSync
Helicity Delay Set : 8 windows
Helicity Delay Read : 8 windows
Helicity Settle Read : 90
Helicity Stable Read : 8243.33
Helicity Pattern Set : Quartet
Helicity Pattern Read : Quartet
Helicity Frequency : 120
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 36mW
Calculated power in cavity : 0.00864909
Photodiode on table : 0
Laser X position on QPD 1 : -665.484
Laser Y position on QPD 1 : 10620.9
Laser X position on QPD 2 : 328.947
Laser Y position on QPD 2 : 553.097
QPD 1 sum : 0.00244156
QPD 2 sum : 0.00488311
Position set point for adjustable
mirror 1 (either x or y) : -10110[c]
Position set point for adjustable
mirror 2 (either x or y) : -7821[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.200
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0433376
Gain of locking servo : 136
Tracking level (V) of locking servo : 1.1
Slow locking signal sent to laser : 0.12635
Fast locking signal sent to laser : -4.63468
Calculated polarisation in cavity : 0
Photodiode 1 after Wollaston prism : 0.00106537
Photodiode 2 after Wollaston prism : 0.00018666
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 162.086
Left Arm Q1 momentum : 0.777075
Left Arm Q1 gauss meter : -0.26824
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 404.983
Left Arm Q2 momentum : 0.932154
Left Arm Q2 gauss meter : 0.21261
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 316.291
Left Arm D1 momentum : 0.952863
Left Arm D1 NMR : 0.352791
Left Arm Q3 power supply current : 459.391
Left Arm Q3 momentum : 0.856788
Left Arm Q3 gauss meter : -0.23185
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 162.03
Right Arm Q1 momentum : 0.808926
Right Arm Q1 gauss meter : -0.23657
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 405.835
Right Arm Q2 momentum : 0.93073
Right Arm Q2 gauss meter : 0.2119
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 327.748
Right Arm D1 momentum : 0.952869
Right Arm D1 NMR : 0.353598
Right Arm Q3 power supply current : 454.7
Right Arm Q3 momentum : 0.842755
Right Arm Q3 gauss meter : 0.2027
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 68.9941
Left Arm Bottom VDC Current : 20.4102
Right Arm Top VDC Current : -4.10156
Right Arm Bottom VDC Current : -5.56641
Left Arm Top VDC voltage : 0.38916
Left Arm Bottom VDC voltage : 0.839844
Right Arm Top VDC voltage : -0.0717773
Right Arm Bottom VDC voltage : -0.0541992
-----------------------------------------
HallA & Injector BCMs and Energy, FFB Variables
-----------------------------------------
Average current of the two cavities : 1.14596
Current on Unser monitor : 4.81305
Current on Upstream bcm : 1.16222
Current on Downstream bcm : 1.13916
Upstream Cavity Coefficient : 38.6
Downstream Cavity Coefficient : 39.8
Current on IBC0L02 (source) : 5.55126
Hall B current : 159.12
Hall C current : 5.04
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
dp/p : 1.58781e-05
MBSY1c Hall A Beam energy : 1.63185e+06
MBSY3c Hall C Beam energy : -4.7699e+06
MBSY1c magnet current (amp) : 39.2847
MBSY1c Bdl : 237276
FB ON, Standby, Pause status : 0
Gain OK or Gain Fail status : 0
Absolute or Relative mode : relative
RF gain high/low : High
Gain mode: manual, automatic : automatic
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 4.9
Raster Y width : 6.3
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -1.15991
IPM1C12.YPOS : 1.1559
IPM1H04A.XPOS : -0.130631
IPM1H04A.YPOS : 0.870724
IPM1H04E.XPOS : -0.253007
IPM1H04E.YPOS : -0.101367
Survey X offset bpm4A : 0
Survey Y offset bpm4A : 0
Survey X offset bpm4B : 0
Survey Y offset bpm4B : 0
Survey X offset bpm12 : -1.15991
Survey Y offset bpm12 : 1.1559
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Moeller Magnet Currents
-----------------------------------------
Moeller ON/OFF : disabled
MQO1H02 Setpoint(Amps) : 21.1926
MQO1H02 Readback(Amps) : 20.63
MQM1H02 Setpoint(Amps) : -18.7778
MQM1H02 Readback(Amps) : -16.6813
MQO1H03 Setpoint(Amps) : 18.2412
MQO1H03 Readback(Amps) : 18.2719
MQO1H03A Setpoint(Amps) : 18.381
MQO1H03A Readback(Amps) : 18.1319
MMA1H01 Setpoint(Amps) : 100
MMA1H01 Readback(Amps) : 0.0381476
----------------------------------------
Beamline Element Temperatures
----------------------------------------
Upstream part of W Collimator : 4.51318
Downstream part of W Collimator : 4.72021
Sieve Box : 5.05762
Beamline : 4.37744