next up previous contents
Next: Efficiency from high electron Up: Long Gas Cherenkov Detector Previous: Corrected ADC spectra within   Contents

Average number of photoelectron for each mirrorr

The average photoelectron number can be obtained by fitting the corrected ADC spectrum within central region of each mirror. The number obtained by Gaussian fit here is roughly 0.8 times real number of photoelectrons.
Mirror# $n_{ph.e.}$
1 6.59
2 7.18
3 8.27
4 9.04
5 8.76
6 10.04
7 10.48
8 7.49
9 8.83
10 7.70



Xiaochao Zheng 2001-05-01