Instrumentation, Controls, Detector, and DAQ related things that need
to be done in Hall A
General Considerations
- Gas Shed
- ethane regulator "chugs"
- update the schematic for the gas systems
- dry air for the hall - replace system with compressor?
- connect argon/ethane manifold pressure sensor to ADC
- re-do Gas Interlock System Master Chassis with
latching signals
- Tech Note for gas flush - make 2 setups
- fabricate a quad gas mixer
- Swap out MFCs in VDC mixing system
- Replace pressure sensors on the Hall A Ethane manifold
- General Stuff
- full list of devices on 188 subnet
- review EPICS Archiver checklists
- SBS GEM's gas mix controller
- communicating with UPSs
- TOF for gas mix monitoring
- Schematic for portable gas mixer - for Whit
- Modify 4-20mA displays to remove 555 timers
- RMS to DC converters to monitor donut transformers
- need a memory test for RPi with background effects
- 555 for radiation damage and CTR circuit
- Must be done - No deadlines involved
- single HV card in a box
- Compton dipole extenders
- VDC wire tension measuring circuit - determine operating
parameters - correct the layout of the
wire tension bridge circuit
- add gas bottle changing procedure to HAWGS
- add flow controller swap procedure to HAWGS
- Both Arms
- On Detector Stacks
- Bogies
- D1
- Q2 and Q3
- Right Arm
- General things to do
- remove shielding on power supply platform
- remove electronics from power supply platform
- remove elctronics from under boxbeam
- Bogies
- On Detector Stack
- Right Q3
- stripped nut on blue busbar inside-front
- black handled switch has problems "catching" when
lowered
- it
often takes a little playing around to get the lever to "catch" when
raised back up
- Right Dipole
- when the supply is off the output current is not reading zero - some small power supplies still getting 120VAC
- Firing problem on SCRs - maybe the firing circuit?
- voltage out of the supply is almost twice that of the
LD1
for the same current
- Right Q2
- 18 bit DAC power supply out of tolerance
- Right Q1
- Left Arm
- General things to do
- remove shielding from power supply platform - leave shielding on beamline side
- On Detector Stack
- carbon doors not fully open
- Left Q3
- is Zero Current LED operating correctly?
- oscillations on current readback 6/29 thru 7/1
- change in ramp up rate - see 06-27
- waver in 480VAC donuts (also in LD1)
- Left Dipole
- Fix LCW leak in LD1 Dynapower
- waver in 480VAC donuts (also in LQ3)
- Left Q2
- Test LQ2 FuG with new polarity reversal switch
- odd, small pulsing in output current - find the source
- noise on the current readback - seems real - can see it
in the hall probe - not in transistor bank voltages
- pulse sense leads to find where break is in wire
- Left Q1
- Replace ground fault module in LQ1 power supply
- power supply does not trip off on loss of
communications
- how should we implement this?
- when the magnet is cycled to 900 amps the UPS under the
Right Boxbeam sends an "on battery" email and "on utility" when brought
down
- install strainer on LCW input line
- Super Big Bite
- General
- Gas system
- Power supply
- Ground fault detector ties one side of supply to ground -
Do we want this?
- LCW flow meter is bad - bogus readings
- install AC power
- Beamline corrector coils
- Big Bite
- General
- Power Supply (BigBox)
- add donut transformers to 480VAC inputs
- no indication when e-stop button pushed on the front of
the supply
- Compton Polarimeter
- In the Hall
- ARC Laser Lab
- 9th Dipole Shed
- install MAGNET ON signs
- scan in papers and manuals
- Moller Polarimeter
- Superconducting Target Magnet
- Controls