Hall A uses RG-58C/U to carry the electrical pulses from the photomultiplier tubes to the trigger electronics. The cables are 37 feet long for most phototubes. All cables carrying phototube signals have a nominal 50 ohm impedance to avoid transmission line mismatches. Some cables have an additional length of RG-174 added. This is done to define a reference time for the detectors.
RG/U Type Cable |
Inner Conductor (Ohms/1000ft) |
Dielectric Material |
DOD | Number/Type of Shielding Braids (Ohms/1000ft) |
O.D. | Weight (lb/ft) |
Nom. Imped. (Ohms) |
Nom. Cap pf/ft |
Max. Operating Voltage (Volts RMS) |
Comments |
---|---|---|---|---|---|---|---|---|---|---|
58 | .0320 BC 0.81 (10.8) |
PE | .116 2.95 |
1 / 95% TC (4.1) |
.195 4.95 |
0.029 | 53.5 | 28.5 | 1400 | Use RG58B |
58A | .0355 0.9 (10.8) |
PE | .116 2.95 |
1 / 95% TC (4.1) |
.195 4.95 |
0.029 | 52 | 28.5 | 1400 | Use RG58C |
58B | .0320 BC 0.81 (10.8) |
PE | .116 2.95 |
1 / 95% TC (4.1) |
.195 4.95 |
0.029 | 53.5 | 28.5 | 1400 | Use up to 1000 MHz |
58C | .0355 0.9 19/.0071 TC 0.8 (10.8) |
PE | .116 2.95 |
1 / 95% TC (4.1) |
.195 4.95 |
0.029 | 50 | 30.8 | 1400 | Extra Flexible Version RG58B |