The wiring from the Terminal Box in Counting Room A to the Terminal Box in Hall A is a direct, one-to-one scheme. That is, terminal screw 1A on terminal strip 1 in the counting room is wired directly to terminal screw 1A on terminal strip 1 in the hall. Terminal strip 1 is on the right hand side as you look from the rear of the rack.



Wiring for Terminal Strip 1 in Terminal Box in Hall A, Rack 1H75B03
Cable, Bundle #1, From Terminal Box in Counting Room A to Terminal Box in Hall A Screw Terminal Number (Terminal strip is mounted inside Terminal Box) Cable, NOT LABLED!, From Terminal Box in Hall A to Gantry Platforms
white8B
black8A
white7B
black7A
white6B
black6A
white5B
black5A
white4Bred (e- gantry)
black (Reset Switch Box #1, switch 12)4Awhite (e- gantry)
white3Bblack (e- gantry)
black (Reset Switch Box #1, switch 11)3Agreen (e- gantry)
white2Bred (e- gantry)
black (Reset Switch Box #1, switch 10)2Agreen (e- gantry)
white1Bblack (e- gantry)
black (Reset Switch Box #1, switch 9)1Awhite (e- gantry)

The remaining pairs are tied together and grounded inside the Terminal Box. Shield drain wires are tied together and grounded inside the Terminal Box.


Wiring for Terminal Strip 2 in Terminal Box in Hall A, Rack 1H75B03
Cable, Bundle #1, From Terminal Box in Counting Room A to Terminal Box in Hall A Screw Terminal Number (Terminal strip is mounted inside Terminal Box) Cable, LABELED?, From Terminal Box in Hall A to rear of detector stack on the Electron Arm
white16Bwhite
black (Reset Switch Box #1, switch 8)16Ablack
white15Bgreen
black (Reset Switch Box #1, switch 7)15Ared
white14Bgreen
black (Reset Switch Box #1, switch 6)14Ablack
white13Bwhite
black (Reset Switch Box #1, switch 5)13Ared
white12Bblue
black (Reset Switch Box #1, switch 4)12Ablack
white11Bred
black (Reset Switch Box #1, switch 3)11Ablack
white10Byellow
black (Reset Switch Box #1, switch 2)10Ablack
white9Bbrown
black (Reset Switch Box #1, switch 1)9Ablack

The black and orange pair are tied together and grounded inside the Terminal Box. Shield drain wires are tied together and grounded inside the Terminal Box.


Wiring for Terminal Strip 3 in Terminal Box in Hall A, Rack 1H75B03
Cable, Bundle #2, From Terminal Box in Counting Room A to Terminal Box in Hall A Screw Terminal Number (Terminal strip is mounted inside Terminal Box) Cable From Terminal Box in Hall A to Beam Line Relay Box RB3
white8B
black (Reset Switch Box #2, switch 8)8A
white7B
black (Reset Switch Box #2, switch 7)7A
white6B
black (Reset Switch Box #2, switch 6)6A
white5B
black (Reset Switch Box #2, switch 5)5A
white4Bblack
(ch4 of Relay Box RB3)
black (Reset Switch Box #2, switch 4)4Ared
(ch4 of Relay Box RB3)
white3Bblack
(ch3 of Relay Box RB3)
black (Reset Switch Box #2, switch 3)3Ared
(ch3 of Relay Box RB3)
white2Bblack
(ch2 of Relay Box RB3)
black (Reset Switch Box #2, switch 2)2Ared
(ch2 of Relay Box RB3)
white1Bblack
(ch1 of Relay Box RB3)
black (Reset Switch Box #2, switch 1)1Ared
(ch1 of Relay Box RB3)

Wiring for Terminal Strip 4 in Terminal Box in Hall A, Rack 1H75B03
Cable, Bundle #2, From Terminal Box in Counting Room A to Terminal Box in Hall A Screw Terminal Number (Terminal strip is mounted inside Terminal Box) Cable, LABLED?, From Terminal Box in Hall A to rear of detector stack on the Hadron Arm
white16Bwhite
black (Reset Switch Box #2, switch 16)16Ablack
white15Bgreen
black (Reset Switch Box #2, switch 15)15Ared
white14Bgreen
black (Reset Switch Box #2, switch 14)14Ablack
white13Bwhite
black (Reset Switch Box #2, switch 13)13Ared
white12Bblue
black (Reset Switch Box #2, switch 12)12Ablack
white11Bred
black (Reset Switch Box #2, switch 11)11Ablack
white10Byellow
black (Reset Switch Box #2, switch 10)10Ablack
white9Bbrown
black (Reset Switch Box #2, switch 9)9Ablack

The remaining pairs are tied together and grounded inside the Terminal Box. Shield drain wires are tied together and grounded inside the Terminal Box.



Back to Jack's Notes