The wiring from the Terminal Box in Counting Room A to the Terminal Box in Hall A is a direct, one-to-one scheme. That is, terminal screw 1A on terminal strip 1 in the counting room is wired directly to terminal screw 1A on terminal strip 1 in the hall. Terminal strip 1 is on the right hand side as you look from the rear of the rack.
Cable, Bundle #1, From Terminal Box in Counting Room A to Terminal Box in Hall A | Screw Terminal Number (Terminal strip is mounted inside Terminal Box) | Cable, NOT LABLED!, From Terminal Box in Hall A to Gantry Platforms |
---|---|---|
white | 8B | |
black | 8A | |
white | 7B | |
black | 7A | |
white | 6B | |
black | 6A | |
white | 5B | |
black | 5A | |
white | 4B | red (e- gantry) |
black (Reset Switch Box #1, switch 12) | 4A | white (e- gantry) |
white | 3B | black (e- gantry) |
black (Reset Switch Box #1, switch 11) | 3A | green (e- gantry) |
white | 2B | red (e- gantry) |
black (Reset Switch Box #1, switch 10) | 2A | green (e- gantry) |
white | 1B | black (e- gantry) |
black (Reset Switch Box #1, switch 9) | 1A | white (e- gantry) |
The remaining pairs are tied together and grounded inside the Terminal Box. Shield drain wires are tied together and grounded inside the Terminal Box.
Cable, Bundle #1, From Terminal Box in Counting Room A to Terminal Box in Hall A | Screw Terminal Number (Terminal strip is mounted inside Terminal Box) | Cable, LABELED?, From Terminal Box in Hall A to rear of detector stack on the Electron Arm |
---|---|---|
white | 16B | white |
black (Reset Switch Box #1, switch 8) | 16A | black |
white | 15B | green |
black (Reset Switch Box #1, switch 7) | 15A | red |
white | 14B | green |
black (Reset Switch Box #1, switch 6) | 14A | black |
white | 13B | white |
black (Reset Switch Box #1, switch 5) | 13A | red |
white | 12B | blue |
black (Reset Switch Box #1, switch 4) | 12A | black |
white | 11B | red |
black (Reset Switch Box #1, switch 3) | 11A | black |
white | 10B | yellow |
black (Reset Switch Box #1, switch 2) | 10A | black |
white | 9B | brown |
black (Reset Switch Box #1, switch 1) | 9A | black |
The black and orange pair are tied together and grounded inside the Terminal Box. Shield drain wires are tied together and grounded inside the Terminal Box.
Cable, Bundle #2, From Terminal Box in Counting Room A to Terminal Box in Hall A | Screw Terminal Number (Terminal strip is mounted inside Terminal Box) | Cable From Terminal Box in Hall A to Beam Line Relay Box RB3 |
---|---|---|
white | 8B | |
black (Reset Switch Box #2, switch 8) | 8A | |
white | 7B | |
black (Reset Switch Box #2, switch 7) | 7A | |
white | 6B | |
black (Reset Switch Box #2, switch 6) | 6A | |
white | 5B | |
black (Reset Switch Box #2, switch 5) | 5A | |
white | 4B | black (ch4 of Relay Box RB3) |
black (Reset Switch Box #2, switch 4) | 4A | red (ch4 of Relay Box RB3) |
white | 3B | black (ch3 of Relay Box RB3) |
black (Reset Switch Box #2, switch 3) | 3A | red (ch3 of Relay Box RB3) |
white | 2B | black (ch2 of Relay Box RB3) |
black (Reset Switch Box #2, switch 2) | 2A | red (ch2 of Relay Box RB3) |
white | 1B | black (ch1 of Relay Box RB3) |
black (Reset Switch Box #2, switch 1) | 1A | red (ch1 of Relay Box RB3) |
Cable, Bundle #2, From Terminal Box in Counting Room A to Terminal Box in Hall A | Screw Terminal Number (Terminal strip is mounted inside Terminal Box) | Cable, LABLED?, From Terminal Box in Hall A to rear of detector stack on the Hadron Arm |
---|---|---|
white | 16B | white |
black (Reset Switch Box #2, switch 16) | 16A | black |
white | 15B | green |
black (Reset Switch Box #2, switch 15) | 15A | red |
white | 14B | green |
black (Reset Switch Box #2, switch 14) | 14A | black |
white | 13B | white |
black (Reset Switch Box #2, switch 13) | 13A | red |
white | 12B | blue |
black (Reset Switch Box #2, switch 12) | 12A | black |
white | 11B | red |
black (Reset Switch Box #2, switch 11) | 11A | black |
white | 10B | yellow |
black (Reset Switch Box #2, switch 10) | 10A | black |
white | 9B | brown |
black (Reset Switch Box #2, switch 9) | 9A | black |
The remaining pairs are tied together and grounded inside the Terminal Box. Shield drain wires are tied together and grounded inside the Terminal Box.