SPEC SHEET HMC1002
(Click here to return to Components Page)
                   
Characteristic Conditions Min Typ Max
Unit
Bridge supply (4) Vbridge referenced to GND  
5
12
Volts
Bridge Resistance Bridge current = 10mA
600
850
1200
ohm
Operating Temperature (4)
-40
 
125
C
Storage Temperature (4) Unbiased
-55
 
125
C
Field Range (1) (2) (4) Full scale (FS), total applied field
-2
 
+2
gauss
Linearity Range (1) (2) (4) Best fit straight line            +/- 1 gauss 
(at 25C)                                +/- 2gauss 
 
0.1
1
0.5
2
%FS
Hysteresis Error (1) (2) (4) 3 sweeps across +/- 2 gauss @ 25C  
0.05
0.01
%FS
Repeatability Error (1) (2) (4) 3 sweeps across +/- 2 gauss @ 25C  
0.05
0.01
%FS
S/R Repeatability (1)
S/R Repeatability (2)
Output variation after alernate S/R pulses  
2
10
100
uV
Bridge Offset Offset=(OUT+) - (OUT-), Field=0 G
after Set pulse, Vbridge=8V
-60
-15
30
mV
Sensitivity (1) (2) At  Ioffset= +/- 50mA, Vbridge=5V
2.5
3.2
4.0
mV/V/gauss
Noise Density (4) Noise at 1Hz, Vbridge=5V  
29
 
nV/ Hz
Resolution (4) Bandwidth=10Hz, Vbridge=5V  
27
 
ugauss
Bandwidth (4) Magnetic signal (low limit=DC)  
5
 
MHz
OFFSET Strap Measured from OFFSET+  to  OFFSET-  
2.5
3.5
ohm
OFFSET Strap Tempco (4) Ta= -40 to 125C   3900  
ppm/C
OFFSET Field (4) Field applied in sensitive direction
46
51
56
mA/gauss
Set/Reset Strap Measured from S/R+ to S/R-  
1.5
1.8
ohm
Set/Reset Current (1) (3) (4) 2us current pulse
3.0
3.2
5
Amp
Disturbing Field (4) Sensitivity starts to degrade.  Use S/R 
pulse to restore sensitivity.
3
   
gauss
Sensitivity Tempco (4) Ta=-40 to 125C                  Vbridge=8V
                                           Ibridge=5mA
-2800
-3000
-600
-3200
ppm/C
Bridge Offset Tempco (4) Ta= -40 to 125C                no Set/Reset
Ibridge=5mA                 With Set/Reset
 
+/-300
+/-10
 
ppm/C
Resistance Tempco (4) Vbridge=8V, -40 to 125C  
2500
 
ppm/C
Cross-Axis Effect (4) Cross field=1 gauss           no Set/Reset
(see AN-205)                  With Set/Reset 
 
+/-3
+/-0.5
 
%FS
Max. Exposed Field (4) No perming effect on zero reading    
100
gauss
Weight HMC1001
HMC1002
 
0.14
0.53
 
gram
        (1) Vbridge=4.3V, Is/r=3.2A, T=25C, Vout=Vset-Vreset.
                      (2) If Vbridge=8V, Is/r=2.0A, T=25C, Lower S/R current leads to greater output variation.
                      (3) Effective current from power supply is less than 1mA.
                      (4) Not tested in production, guaranteed by characterization.

                        Units:  1 gauss (g) = 1 Oersted (in air), =79.58 A/m, 1G= 10E-4 Tesla, 1G=10E6 gamma