SPEC SHEET HMC1021S
(Click here to return to Components Page)
                                                 
Characteristic Conditions Min Typ Max
Unit
Bridge supply  Vbridge referenced to GND  1.8
2.5
20
Volts
Bridge Resistance Bridge current = 1mA  
1000
 
ohm
Storage Temperature  Ambient, Unbiased
-55
 
125
C
Operating Temperature Ambient
-40
 150
C
Field Range  Full scale (FS), total applied field
-6
 
+6
gauss
Linearity Range  Best fit straight line               +/- 1 gauss
(at 25C)                             +/- 3 gauss
                                           +/- 6 gauss
 
0.05
0.4
1.6
0.5
2
%FS
Hysteresis Error  3 sweeps across +/- 3 gauss @ 25C  
0.1
 
%FS
Repeatability Error  3 sweeps across +/- 3 gauss @ 25C  
0.1
 
%FS
Bridge Offset Offset=(OUT+) - (OUT-), Field=0 G
Field=0 Gafter Set pulse, Vbridge=5V
 
+/- 1
 
mV
Sensitivity  Set/Reset Current=0.5A  
1.0
 
mV/V/gauss
Bandwidth  Magnetic signal (low limit=DC)  
5
 
MHz
OFFSET Strap Measured from OFFSET+  to  OFFSET-  
15
 
ohm
OFFSET Strap Tempco  Ta= -40 to 125C   3900  
ppm/C
OFFSET Strap Constant  Field applied in sensitive direction
4.0
4.6
6.0
mA/gauss
Set/Reset Strap Measured from S/R+ to S/R- (DC current)
6
7.7
9
ohm
Set/Reset Current  2us current pulse
0.5
0.5
4.0
Amp
Disturbing Field  Sensitivity starts to degrade.  Use S/R 
pulse to restore sensitivity.
20
   
gauss
Sensitivity Tempco  Ta=-40 to 125C                  Vbridge=5V
                                           Ibridge=5mA
-2800
-3000
-600
-3200
ppm/C
Bridge Offset Tempco  Ta= -40 to 125C                no Set/Reset
Ibridge=5mA                 With Set/Reset
 
+/-500
+/-10
 
ppm/C
Resistance Tempco  Vbridge=5V, -40 to 125C  
2500
 
ppm/C
Cross-Axis Effect  Cross field=1 gauss 
(see AN-205)        Happlied=+/- 1 gauss 
 
+0.3
 
%FS
Max. Exposed Field  No perming effect on zero reading    
200
gauss
Set/Reset  S/R current >= Amps    
30
uV
* Tested at 25C except stated otherwise  Units:  1 gauss (g) = 1 Oersted (in air), =79.58 A/m, 1G= 10E-4 Tesla, 1G=10E6 gamma

Please direct all product-related questions to your Sales Representative, and web-site comments to webmaster.ssec@honeywell.com.

Copyright © 2000 by Honeywell International. All rights reserved. (Legal Notice)