SPEC SHEET HMC1023
(Click here to return to Components Page)
 
Characteristic Conditions Min Typ Max
Unit
Bridge supply  Vbridge referenced to GND  
5
12
Volts
Bridge Resistance (2) Bridge current = 5mA
800
1100
1300
ohm
Operating Temperature  HMC1021S, 1021Z, 1022
HMC1021D *
-40
-40
 
125
300*
C
Storage Temperature  Unbiased
-55
 
125
C
Field Range  Full scale (FS), total applied field
-6
 
+6
gauss
Linearity Range  Best fit straight line               +/- 1 gauss
(at 25C)                             +/- 3 gauss
                                           +/- 6 gauss
 
0.05
0.4
1.6
0.5
2
%FS
Three-Axis Orthoganality Angle from 90 degrees  
+/- 1
 
degrees
Hysteresis Error  3 sweeps across +/- 3 gauss @ 25C  
0.08
 
%FS
Repeatability Error  3 sweeps across +/- 3 gauss @ 25C  
0.08
 
%FS
Bridge Offset Offset=(OUT+) - (OUT-), Field=0 G
after Set pulse, Vbridge=5V
-10
+/-2.5
+10
mV
Sensitivity  At  Vbridge=5V
.8
1.0
1.2
mV/V/gauss
Noise Density  Noise at 1Hz, Vbridge=5V  
48
 
nV/ Hz
Resolution  Bandwidth=10Hz, Vbridge=5V  
85
 
ugauss
Bandwidth  Magnetic signal (low limit=DC)  
5
 
MHz
OFFSET Strap Measured from OFFSET+  to  OFFSET-
40
50
60
ohm
OFFSET Strap Tempco  Ta= -40 to 125C   3900  
ppm/C
OFFSET Field  Field applied in sensitive direction
4.0
4.6
6.0
mA/gauss
Set/Reset Strap (1) Measured from S/R+ to S/R-
2.0
3.0
4.0
ohm
Set/Reset Current (1) 2us current pulse
1.5
2.0
4.0
Amp
Disturbing Field  Sensitivity starts to degrade.  Use S/R 
pulse to restore sensitivity.
20
   
gauss
Sensitivity Tempco  Ta=-40 to 125C                  Vbridge=5V
                                           Ibridge=5mA
-2800
-3000
-600
-3200
ppm/C
Bridge Offset Tempco  Ta= -40 to 125C                no Set/Reset
Ibridge=5mA                 With Set/Reset
 
+/-500
+/-10
 
ppm/C
Resistance Tempco  Vbridge=5V, -40 to 125C  
2500
 
ppm/C
Cross-Axis Effect  Cross field=1 gauss 
(see AN-205)        Happlied=+/- 1 gauss 
 
+0.3
 
%FS
Max. Exposed Field  No perming effect on zero reading    
200
gauss
          *Please reference data sheet, HTMC1021D for specification.
                                      (1) Not tested in production. gauaranteed by characterization.
                                      (2) Vcc to Gnd resistance ~ 350 ohms, three 1k ohms bridges in parallel
                   Units:  1 gauss (g) = 1 Oersted (in air), =79.58 A/m, 1G= 10E-4 Tesla, 1G=10E6 gamma