SPEC SHEET HMC1512
(Click here to return to Components Page)
Characteristics
Conditions
 HMC1501
HMC1512
 Units
Min Typ Max Min Typ Max
Bridge supply
Vbridge referenced to GND
1
5
25
1
5
25
V
Bridge resistance
Bridge current--1mA
4
5
6.5
2.0
2.1
2.8
Kohm
Sensitivity
Vbridge=5V, field 80 Oe,
(1) @ zero crossing
(2) @ zero crossing, averaged
           in the range of 45 °
 
2.1
1.8
   
2.1
1.8
 
mV/°
Peak-to-Peak Voltage
Vbridge=5V, field 80 Oe
100
120
140
100
120
140
mV
Bridge offset
  Field 80 Oe, 0 °     Bridge A
                                      Bridge B
-7
 3
7
0
-4
2.5
0
5
1
mV/V
Saturation field
Repeatability <0.03% FS
 80      80      
Bandwidth
Magnetic signal
0
 
5
0
 
5
MHz
Resolution
Bandwidth=10Hz, Vbridge=5V
 
0.07
   
0.05
 
deg
Hystersis error
Magnetic field>=saturation field,
Vbridge=5V
 
30
.017
   
30
.017
 
uV
deg
Bridge W Tempco
TA= -40°C to +125°C
 
0.28
   
0.28
 
%/°C
Angle range
>= Saturation field
-45
 
+45
-90
 
+90
deg
Sensitivity tempco*
TA= -40°C to +125°C
Vbridge=5V
 
-0.32
   
-0.32
 
%/°C
Bridge offset tempco**
TA= -40°C to +125°C
 
-0.01
   
-0.01
 
%/° C
FS
Noise Density
Noise @ 1Hz, Vbridge=5V
 
100
   
70
 
nV/Hz
Power Consumption***
Vbridge=5V
 
5
   
23
 
mW

*Sensitivity tempco Cs =(St-So)/(So*t )= -0.32% %/°C

Where            So = sensitivity at zero temperature
                        t = temperature in the range -40°C to 125°C
                        St = sensitivity at temperature t

**Offset tempco Co = (Vo (t) - Vo (o) )/(VP-P*t)= -0.01% %/°C
 Where           Vo (o) = bridge offset at zero temperature
                        VP-P = peak-to-peak voltage
                        t = temperature in the range -40°C to 125°C
                        Vo (t) = offset at temperature t

***Power consumption  P=V^2/R
 Where           V = Bridge supply voltage
                        R = Bridge resistance

1 KA/m = 12.5 Gauss