A/D
12-bit resolution,
500 KHz max. total sampling rate (#ch * rate), 32 channels (16
differential)
Maximum input range +/- 10 Volts
Gains: 1, 4, 10, 40, 100,
400
Data rate for client computer download: 5 to 10 Ksamples/sec (binary
mode), depending on format options
Unless otherwise noted specs are worst case maximum at instrument calibration temperature. Values are preliminary, and will be updated to include typical values when that information is available. All LSB units are expressed in terms of a 12-bit resolution least-significant-bit (e.g., 4.88mV at gain 1, or 48.8 uV at gain 100).
System Gain 1 , 4: | 80 dB min 100 dB typical |
System Gain 10 , 40: | 86 dB min 110 dB typical |
System Gain 100 , 400: | 92 dB min 120 dB typical |
Details/notes:
Factory and self-calibration adjust the D/A range
and offset to provide accurate output. In the process, the D/A bit resolution
may be adjusted slightly, so the minimum D/A step size can vary from approx.
21.5 mV to 23.5 mV.
Communication Ports
Environmental
Digital I/O
4 bits input, can be
time-sampled, standard TTL logic voltage levels
4 bits output, can do timed
pattern generation
standard TLL logic levels, current drive capability: -15mA
source, 24mA sink
Ethernet 10-baseT
with RJ45 connector
Serial (RS-232) 9-pin connector, DTE, default set to
38400 baud, 8 bits, no parity, 1 stop bit
Power Supply
·
90 - 264 VAC
·
47 to 63 Hz
·
Approx. 18 watts power consumption
Size and Weight
Dimensions
7.5" x
10.375" x 2.675"
19cm x
26.5cm x 7cm
Weight
34
oz.
965
gm
Shipping box
12.375" x 14.5" x 5"
31.5cm
x 37cm x 13cm
4.6 lb
2.1
kg
Power
supply
2.125"
x 4.5" x 1.75"
5.5cm
x 11.5cm x 4.5cm
20 oz
with line cord
570
gm
RAM memory
·
72-pin SIMM module
·
Page-mode memory
·
70 nsec or less access time
·
size: 4MB, 8MB, 16MB, 32MB, 64MB or 128MB
operating:
0 degrees C to +40 degrees C.
non-operating:
-10 degrees C to +70 degrees C.
0%
to 90% relative humidity (non-condensing)
Certifications
United States:
Conforms
to the requirements of:
FCC Rules and Regulations, Part 15, Subpart B, Class
A
Radiated Emissions: - Para. 15.109(b)
Conducted Emissions: - Para.
15.107(b)
Canada:
This Class A digital apparatus meets all requirements
of the Canadian Interference-Causing Equipment Regulations.
European Union: Conforms to the requirements of: EN
61326:1998
Emissions requirements of EN 61326:1998
Class A, Conducted
Emissions, 150 kHZ to 30 MHz
Class A, Radiated Emissions, 30 MHZ to 1
GHz
Immunity requirements of EN 61326:1998
IEC 1000-4-2:1995 Electrostatic
discharge, 8 KV Direct Air, 4 KV Direct and Indirect Contact.
IEC
1000-4-3:1995 Radiated RF Immunity, 80 MHz - 1000 MHz, 10V/m, 80% AM 1
KHz.
IEC 1000-4-4:1995 EFT, 2KV Direct to Power Leads, 1KV to I/O Leads
through Coupling Clamp.
IEC 1000-4-5:1995 Surge Immunity, 2KV Common Mode, 1
KV Differential Mode.
IEC 1000-4-6:1995 Conducted RF Immunity, 150 KHz - 80
MHz, 3 Vrms, 80% AM 1KHz.
IEC 1000-4-8:1995 Magnetic Immunity, 50 Hz, 30
A/m
IEC 1000-4-11:1994 Voltage Dips and Short Interruptions
Australia:
Conforms to the requirements of: AS/NZS 3548
Japan:
Conforms to the requirements of: VCCI V-3/99.05 AMD June
1999, for Class A, ITE, Conducted and Radiated Disturbance.
Disclaimer
The information contained in this documentation is believed to be accurate and reliable. However, Capital Equipment assumes no responsibility for its use or for any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent rights of Capital Equipment. This documentation is copyrighted by Capital Equipment. Copyright 2000. |
Please see printed materials for a statement of warranties. Except as specified in written materials accompanying the product, Capital Equipment makes no warranties, express or implied of merchantability or fitness for a particular purpose. Customer's right to recover damages shall be limited to recovery of the purchase price. Capital Equipment shall not be liable for damages resulting from loss of data, profits, use of products, or incidental or consequential damages, even if advised of the possibility thereof. This product is not designed with components of a level of reliability suitable for use in treatment or diagnosis of humans, life support or clinical applications. webDAQ and webDAQ/100 are trademarks of Capital Equipment. All rights reserved. |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |