March 3, 2008 - Valencia, California |
|
Late last year, Hakko began to globalize the T7 Series Composite Tips under new part numbers. These new tips are the T15 Series Composite Tips. As a result of this globalization effort, Hakko FM-202 customers that use T15 Series Tips may now change the software setting of their soldering station to turn off the Process Gate
If you are using T15 Series Tips and would like to turn off the Process Gate on your FM-202 Soldering Station, please review and follow the steps below:
|
1. |
With the unit power turned off, insert the lockout key card into the slot in the front of the FM-202. |
|
2. |
While holding down the (pound) and (down arrow) keys, turn the power on. |
|
3. |
When the display shows with the last digit flashing, release the buttons. |
|
4. |
Press the (down arrow) key one time to change the last digit to a (zero). |
|
5. |
Press the (star) key repeatedly to accept this change and to move through the remaining parameters. The display will read the set temperature of your FM-202 when you have finished. |
|
6. |
When the set temperature is displayed, hold down the (pound) key. |
|
7. |
When the display reads with the first digit flashing, release the (pound) key. |
|
8. |
Press the (star) key to accept (zero) as the first digit. |
|
9. |
The second digit will begin flashing. Press the (up arrow) key one time to change the (zero) to a (one) and press the (star) key to accept. |
|
10. |
The last digit will begin flashing. Press the (up arrow) repeatedly until the value reads (five). Press the (star) key to accept. |