The P6137 is a compact, 1.5 meter, 10X, passive voltage probe designed specifically for use with the TEKTRONIX 2400 Series oscilloscopes. It is fully compatible with the Tektronix family of compact pr-)be accessories.
Electrical Characteristics (Probe installed on 2400 Series Oscilloscopes) | |
Attenuation: | 1 OX +/- 1 % at dc. |
Input Impedance (System): | 1 0 M ohm shunted by 10.8 pF at DC (See Figure 1.) |
Compensation Range: | 12 pF to 18 pF. |
Signal Delay: | Delay difference between any two probes of equal length is <200 ps. |
System Bandwidth (-3dB): | Use of the P6137 on a 2400 Series oscilloscope with a bandwidth measured to be greater than 350 MHz from a properly terminated 50 ohm source, and having an input capacitance of 15 pF +/- 2 pF, will result in a system bandwidth of at least 350 MHz. A similar correspondence is achieved for all 2400 Series oscilloscopes of identical input capacitance and different bandwidths up to a system maximum bandwidth of 400 MHz. |
Maximum Nondestructive Input Voltage: | 500 V (dc + peak ac) to 1.3 MHz. (See Figure 2 for voltage derating curve.) |
System Aberrations less oscilloscope's 50-ohm-DC coupled aberrations: | 4% overshoot, during first 2 ns, <= +/-3%, 5% p-p in the following 30 ns, +/-l %,l % p-p thereafter. |
Environmental Characteristics | |
Temperature Range (Operating): | - 15'C to +75'C (+5'F to +167'F). |
Temperature Range (Nonoperating): | - 62'C to + 85'C (- 80'F to +185 'F). |
Humidity: | Five cycles (120 hr) at 95% to 97% relative humidity. Per Tek Standard O62-2847-00,Class 3. ReftoMIL-E-16400F,paragraph4.5.9through4.5.9.5.1,class4. |
Physical Characteristics | |
Net Weight (includes Accessories): | 168 g (6 oz). |
Probe Cable Length: | (1.5 m ~= 5 ft). |
[ Home ]