keyword=Signs of beam asymmetries for HRS and Moller
16:15 measuring the beam charge asymmetry with the HRS DAQ
and with Moller DAQ
1) apply_feedback 1 0
runs: 2361, 20771, Moller 12560
feedback runs Asymmetry, %
HRLS HRSR Moller HRSL HRSR Moller
0 2361 20771 12560 -0.63 -0.63 0.61+/-0.03
5 2362 20772 12561 0.007 0.02 -0.03+/-0.008
10 2363 20773 12564 0.96 0.87 -0.70+/-0.01
We wanted to have a 30min HRS run with feedback=10 in order
to check the asymmetry with the triggers, but the beam
went away and we stopped the test. The scaler data should