Difference between revisions of "Preparation"
From Hall A Wiki
(New page: * Cable/HRS motion: add cable length and re-route the needed cables. Disconnect the others ? * Left cerenkov overflow: move ADC from ROC 3 to ROC 4. Could we split the signal between the e...) |
|||
Line 1: | Line 1: | ||
* Cable/HRS motion: add cable length and re-route the needed cables. Disconnect the others ? | * Cable/HRS motion: add cable length and re-route the needed cables. Disconnect the others ? | ||
+ | |||
* Left cerenkov overflow: move ADC from ROC 3 to ROC 4. Could we split the signal between the existing ADC in ROC 3 and the ADC in ROC 4 ? | * Left cerenkov overflow: move ADC from ROC 3 to ROC 4. Could we split the signal between the existing ADC in ROC 3 and the ADC in ROC 4 ? | ||
+ | |||
* Deadtime: | * Deadtime: | ||
- remove the sequencer reading of BB and only read the main trigger module. | - remove the sequencer reading of BB and only read the main trigger module. | ||
- or set hight threshold on unused channels. | - or set hight threshold on unused channels. | ||
+ | |||
* RIght arm Shower block 76 missing signal | * RIght arm Shower block 76 missing signal | ||
+ | |||
* Right arm Cerenkov: | * Right arm Cerenkov: | ||
- multi-peak in the TDCs: gate width problem ? | - multi-peak in the TDCs: gate width problem ? | ||
- no obvious single photon electron peak in ADCs: increase HV. | - no obvious single photon electron peak in ADCs: increase HV. | ||
+ | |||
+ | * Right Q3: run Q3 at momentum 15% lower for each momentum setting. |
Revision as of 21:11, 10 April 2011
- Cable/HRS motion: add cable length and re-route the needed cables. Disconnect the others ?
- Left cerenkov overflow: move ADC from ROC 3 to ROC 4. Could we split the signal between the existing ADC in ROC 3 and the ADC in ROC 4 ?
- Deadtime:
- remove the sequencer reading of BB and only read the main trigger module. - or set hight threshold on unused channels.
- RIght arm Shower block 76 missing signal
- Right arm Cerenkov:
- multi-peak in the TDCs: gate width problem ? - no obvious single photon electron peak in ADCs: increase HV.
- Right Q3: run Q3 at momentum 15% lower for each momentum setting.