Difference between revisions of "Cryo-target wall contamination"
From Hall A Wiki
(→Kinematic 6.5) |
|||
Line 72: | Line 72: | ||
Result: An estimate of 4439 events wall events remains within the cut ==> Contamination is 4%. | Result: An estimate of 4439 events wall events remains within the cut ==> Contamination is 4%. | ||
− | |||
Line 78: | Line 77: | ||
[[Image:dummy_6.5_all.gif]] | [[Image:dummy_6.5_all.gif]] | ||
+ | |||
+ | |||
+ | * With the full statistic collected till run 4039: | ||
+ | |||
+ | [[Image:dummycont_6.5.gif]] |
Revision as of 14:48, 1 May 2011
The normalized yield is equal to Ngood/Q/density. Here I neglected the density of the 3He gas.
Kinematic 5.2
Target | window thickness | Total charge | # of good evts | |
---|---|---|---|---|
upstream | downstream | |||
He3 | 0.0274 cm | 0.0328 cm | 6.92E+8 | 253254 |
Dummy | 0.1581 cm | 0.1585 cm | 2.16E+8 | 3588 |
Result: An estimate of 2186 events wall events remains within the cut ==> Contamination is less than 1%.
Kinematic 6.5
Target | window thickness | Total charge | # of good evts | |
---|---|---|---|---|
upstream | downstream | |||
He3 | 0.0274 cm | 0.0328 cm | 1.045E+9 | 110050 |
Dummy | 0.1581 cm | 0.1585 cm | 1.316E+7 | 294 |
Result: An estimate of 4439 events wall events remains within the cut ==> Contamination is 4%.
- With the full statistic collected till run 4039: