Difference between revisions of "Solid Detector Dimension"

From Hall A Wiki
Jump to: navigation, search
(SoLID CLEO (based on CLEOv8 field map))
(Introduction)
Line 3: Line 3:
 
The SoLID layouts with different configuration are shown here.
 
The SoLID layouts with different configuration are shown here.
  
The standard 3D plot can be download on this page and 2D plots are [https://hallaweb.jlab.org/wiki/index.php/Solgemc_GDML_Visualization here]
+
The standard setup plot can be download from http://hallaweb.jlab.org/12GeV/SoLID/download/sim/setup/
  
 
  coil center at z=0
 
  coil center at z=0

Revision as of 00:45, 14 December 2012

Introduction

The SoLID layouts with different configuration are shown here.

The standard setup plot can be download from http://hallaweb.jlab.org/12GeV/SoLID/download/sim/setup/

coil center at z=0

current

SoLID CLEO (based on CLEOv8 field map)

CLEOv8 field map is based on more realistic design with CLEO-II.

The magnet and yoke will fit both PVDIS and SIDIS/JPsi configuration.

The detector has various small change to fit into new design, please refer to the change at slide 7 and 8 of CLEOv8 update pptx pdf

SIDIS/JPsi
Solid CLEO SIDIS 3he 20120821.png
Z center (cm) Z range (cm) Z length (cm) R range (cm) R length (cm) area (m2) weight(metric t) comment
target (SIDIS) -350 (-370,-330) 40 (0,1) 1
target collimator upstream (SIDIS) -355 (-360,-350) 10 Rin(1.2,2.4),Rout(4.9,9.8) made of W
target collimator downstream (SIDIS) -300 (-305,-295) 10 Rin(5.5,6.8),Rout(21.9,26.8) made of W
GEM Z(-175,-150,-119,-68,5,92) 1 per plane Rin(45,26,30,37,46,58), Rout(80,93,107.5,135,98,122) (35,67,77.5,98,52,64)
largeangle Calorimeter -40 Z(-65,-15) 50 Rin(75, 88),Rout(140, 140) (66,50) 4.5 9 (25%lead + 75%scintillator)
absorber largeangle 70 Z(60,80) 20 Rin(107.5,112.8),Rout(140,140) (32.5,27.2) 2.3 9 (Tungsten)
absorber forwardangle 140 Z(100,180) 80 Rin(16,19),Rout(50,60) (34,39) 0.85 13 (Tungsten) can be smaller
lightgas Cherenkov Z(97,194,209,301) 204 Rin(58,65,67,85), Rout(127,144,155,265) (69,79,88,180)
heavygas Cherenkov 351 Z(306,396) 90 Rin(86,98),Rout(265,265) (179,167)
MRPC 400 1 (99,201) 101
forwardangle Calorimeter 430 (405,455) 50 (100,215) 115 11.4 23 (25%lead + 75%scintillator) may share supporting with PVDIS FAEC
Space at back (455,485) 30 partially for EC readout
Beamline upstream Z(-675,-375) 300 Rin(1.22,1.22), Rout(1.25,1.25) 0.03
Beamline downstream Z(-325,500) 825 Rin(1.7,28.9),Rout(1.8,29.0) 0.1


PVDIS
Solid CLEO PVDIS 20120821.png
Z center (cm) Z range (cm) Z length (cm) R range (cm) R length (cm) area (m2) weight (t) comment
target 10 (-10, 30) 40 (0, 1) 1
Baffle Z(40,68,96,124,152,180) 9 per plate Rin(3.9,15.3,26.6,37.9,49.2,60.4) Rout(34.7,54.3,73.8,93.3,112.8,132.0) (30.8,39,47.2,93,55.4,63.6,71.6) 15 Eugene's baffle for BaBar
GEM Z (157.5,185.5,306,315) 1 per plate Rin(56,67,113,117),Rout(108,129,215,222) (52,62,102,105)
lightgas Cherenkov Z(194,209,301) 107 Rin(65,67,85),Rout(144,155,265) (79,88,180)
forwardangle Calorimeter 345 (320,370) 50 (118,261) 143 17 34 (25%lead + 75%scintillator) may share supporting with SIDIS FAEC
Space at back 370 - 485 115 partially for EC readout
Beamline upstream Z(-675,-15) 650 Rin(1.22,1.22), Rout(1.25,1.25) 0.03
Beamline downstream Z(35,500) 465 Rin(1.4,28.9),Rout(1.5,29.0) 0.1

previous

SoLID CLEO (based on CLEOv5 field map)

The detectors are copied from SoLID BaBar, but with longer Calorimeter.

SIDIS CLEO
Solid CLEO SIDIS 20111012.png
Z range (cm) Z center (cm) Z length (cm) R range (cm) R length (cm)
target -370 - -330 -350 40 0 - 1 1
GEM
largeangle Calorimeter -65.5 - -15.5 -40.5 50 82 - 141 59
lightgas Cherenkov 97 - 225 - 301 161, 263 204 67 - 160 - 265 198
SC 303.75 - 304.25 304 0.5 95 - 177 82
heavygas Cherenkov 306 - 396 351 90 96- 265 169
MRPC 397 - 399 398 2 115 - 195 90
forwardangle Calorimeter 400 - 450 425 50 120 - 202 95
empty space at back 450 - 480 465 30


PVDIS CLEO
Solid CLEO PVDIS 20111012.png
Z range (cm) Z center (cm) Z length (cm) R range (cm) R length (cm)
target -10 - 30 10 40
GEM #1 #2
Cherenkov 200 - 225 - 301 212.5, 262.5 25, 75 61 - 260 199
GEM #3 305.52 - 306.48 306 0.96 105 -200 95
GEM #4 320.52 - 321.48 321 0.96 115 -215 100
forwardangle Calorimeter 325 - 375 350 50 110 - 265 155
empty space at back 375 - 405 390 30


SoLID BaBar (based on BABARv4 field map)

The detectors converted from comgeant configuration at the proposal stage, then modified with longer Cherenkov.

SIDIS BaBar
Solid BaBar SIDIS 20111012.png
Z range (cm) Z center (cm) Z length (cm) R range (cm) R length (cm)
target -370 - -330 -350 40 0 - 1 1
GEM
largeangle Calorimeter -65.5 - -35.5 -50.5 30 82 - 141 59
lightgas Cherenkov 97 - 225 - 301 161, 263 204 67 - 160 - 265 198
SC 303.75 - 304.25 304 0.5 95 - 177 82
heavygas Cherenkov 306 - 396 351 90 96- 265 169
MRPC 397 - 399 398 2 115 - 195 90
forwardangle Calorimeter 400 - 430 415 30 120 - 202 95



PVDIS BaBar
Solid BaBar PVDIS 20111012.png
Z range (cm) Z center (cm) Z length (cm) R range (cm) R length (cm)
target -10 - 30 10 40
GEM #1 #2
Cherenkov 200 - 225 - 301 212.5, 262.5 25, 75 61 - 260 199
GEM #3 305.52 - 306.48 306 0.96 105 -200 95
GEM #4 320.52 - 321.48 321 0.96 115 -215 100
forwardangle Calorimeter 325 - 375 350 50 110 - 265 155