Difference between revisions of "Solid Background"

From Hall A Wiki
Jump to: navigation, search
(tool "background")
Line 29: Line 29:
 
http://hallaweb.jlab.org/12GeV/SoLID/download/sim/background
 
http://hallaweb.jlab.org/12GeV/SoLID/download/sim/background
  
*.root is from GEMC, *.txt is all FLUX banks output from *.root, background.C runs on *.txt to produce *_output.root which has rate and Eflux on all detectors
+
*.root is from GEMC, *.txt is all FLUX banks output from *.root, background.C runs on *.txt to produce *_output.root which has rate and Eflux on all detectors
  
 
     histogram "Eklog_R_hitid_pid" shows R(cm) VS log10(Ek) (GeV) at different detector and for different particles
 
     histogram "Eklog_R_hitid_pid" shows R(cm) VS log10(Ek) (GeV) at different detector and for different particles
 
 
     pid=0  photon+electron+positron
 
     pid=0  photon+electron+positron
 
         1  photon     
 
         1  photon     
Line 44: Line 43:
 
         9  Kl
 
         9  Kl
 
       10  other
 
       10  other
 
 
   hitid=0 - 5  GEM plane 1 - 6
 
   hitid=0 - 5  GEM plane 1 - 6
 
         6      lightgas CC  
 
         6      lightgas CC  

Revision as of 10:02, 21 March 2013

some estimation

PVDIS

50uA, 
LH target, 40cm, 0.071g/cm3, X=50/890.4=4.5e-2, Lumi=50e-6/1.6e-19*40*0.071*6.02e23=0.53e39/cm2/s 
LD target, 40cm, 0.169g/cm3, X=50/745.4=5.4e-2, Lumi=50e-6/1.6e-19*40*0.169*6.02e23=1.27e39/cm2/s
Al window, 2*100um, density 2.7g/cm3, X=2*100e-4/8.897=2.25e-3, Lumi=50e-6/1.6e-19*2*100e-4*2.7*6.02e23=1e37/cm2/s

SIDIS 3he

15uA
3he(10amg), 40cm, density=10*44.6(amg=mol/m3)*3.016(g/mol)=1.345e-3g/cm3, X=40/(67.42/1.345e-3)=0.8e-3, Lumi=15e-6/1.6e-19*40*1.345e-3*6.02e23=3e36/cm2/s
GE180 glass window, 2*120um, density 2.76g/cm3, X=2*120e-4/(19.4/2.76)=3.4e-3, Lumi=15e-6/1.6e-19*2*120e-4*2.76*6.02e23=3.7e36/cm2/s

SIDIS proton

100nA
NH3

JPsi

3uA
LH target, 15cm, 0.071g/cm3, X=15/890.4=1.7e-2, Lumi=3e-6/1.6e-19*15*0.071*6.02e23=1.2e37/cm2/s
Al window, 2*100um, density 2.7g/cm3, X=2*100e-4/8.897=2.25e-3, Lumi=3e-6/1.6e-19*2*100e-4*2.7*6.02e23=6e35/cm2/s

tool "background"

The code is in SVN at https://jlabsvn.jlab.org/svnroot/solid/solid_gemc/analysistool/background

The result is here http://hallaweb.jlab.org/12GeV/SoLID/download/sim/background

*.root is from GEMC, *.txt is all FLUX banks output from *.root, background.C runs on *.txt to produce *_output.root which has rate and Eflux on all detectors
   histogram "Eklog_R_hitid_pid" shows R(cm) VS log10(Ek) (GeV) at different detector and for different particles
   pid=0   photon+electron+positron
       1   photon    
       2   electron + positron
       3   neutron
       4   proton
       5   pip
       6   pim
       7   Kp
       8   Km
       9   Kl
      10   other
  hitid=0 - 5  GEM plane 1 - 6
        6       lightgas CC 
        7       heavygas CC 
        8 - 11  FAEC front,middle,inner,rear 
        12 -15  LAEC front,middle,inner,rear 
        16 - 17 MRPC front,within

PVDIS Geant4 modeled background from Target

Rates and flux from GEMC for PVDIS follow. Validation against GEANT3 can be found here: Compare_to_geant3_result.

Rates on GEMs for 50uA on LH2. Solid lines are unbaffled, dashed are with lead baffles:

Geant4 truegemrate.png

Flux in EM calorimeter for 50uA on LH2. Solid lines are unbaffled, dashed are with lead baffles. The true rate should be taken from the black lines.

Emflux.png

SIDIS Geant4 modeled background from Target

Sidisgem.png

<math>\pi</math>/e Ratio

See here