Line 24: Line 24:
 
Noisy  
 
Noisy  
  
 
+
maybe bad box : 127 to 139
  
 
No signal PMT
 
No signal PMT
150 ( low gain ? )
+
150 ( will put HV to 0 since might be origin of noise )
  
  
 
No signal ADC
 
No signal ADC
 
74 looks like bad channel, DC offset was tuned twice and big , to be moved on another channel
 
74 looks like bad channel, DC offset was tuned twice and big , to be moved on another channel
 
+
125
96 need to be recrimped
+

Revision as of 21:59, 27 October 2007

Look at data =

Coulomb Sum Rule


Use :

.x online.C+("CSR",run)

latest run is 1307


Bad Channels, things to check, fix

( in channel number = histogram number +1 )

Big pedestal value


Signal but negative signal ( Offset )


Noisy

maybe bad box : 127 to 139

No signal PMT 150 ( will put HV to 0 since might be origin of noise )


No signal ADC 74 looks like bad channel, DC offset was tuned twice and big , to be moved on another channel 125