Difference between revisions of "How to start EDTM pulser (experts only)"
Line 1: | Line 1: | ||
1 Open a terminal from any computer in counting house and type the command: | 1 Open a terminal from any computer in counting house and type the command: | ||
− | -> | + | ->telnet hatsv4 2004 |
2 After connecting to that port and hitting the enter key, a prompt should pop up and we can set the EDTM pulser rate by the following command: | 2 After connecting to that port and hitting the enter key, a prompt should pop up and we can set the EDTM pulser rate by the following command: | ||
− | -> | + | ->r_pulser_Start(0,0xa100,0xc339) |
The meaning of the arguments are explained below. | The meaning of the arguments are explained below. | ||
3 To quit from telnet, hold the "'''ctrl'''" key and hit "''']'''". we should then see a prompt like "telnet>". Now type "'''q'''" to close the connection. | 3 To quit from telnet, hold the "'''ctrl'''" key and hit "''']'''". we should then see a prompt like "telnet>". Now type "'''q'''" to close the connection. | ||
+ | |||
+ | The EDTM pulse is now supplied by a synchronous pulser generator based on VME programmable logic. The generator has two synchronous outputs and the output rates are controlled by the second and third argument in the function r_pulser_Start() respectively. Currently the second output is used to feed the EDTM module and the first output is irrelevant. We shall set the first argument in function r_pulser_Start() to be 0 to set the rate of both outputs of the pulser generator. | ||
+ | |||
+ | The table showing the correspondence between the pulser rate and the hexadecimal words used in the r_pulser_Start() function can be found by typing the following command in a terminal opened on a computer in the counting house: | ||
+ | >less /adaqfs/home/adaq/vme/rpulser/obs.txt |
Revision as of 11:47, 6 October 2014
1 Open a terminal from any computer in counting house and type the command:
->telnet hatsv4 2004
2 After connecting to that port and hitting the enter key, a prompt should pop up and we can set the EDTM pulser rate by the following command:
->r_pulser_Start(0,0xa100,0xc339)
The meaning of the arguments are explained below.
3 To quit from telnet, hold the "ctrl" key and hit "]". we should then see a prompt like "telnet>". Now type "q" to close the connection.
The EDTM pulse is now supplied by a synchronous pulser generator based on VME programmable logic. The generator has two synchronous outputs and the output rates are controlled by the second and third argument in the function r_pulser_Start() respectively. Currently the second output is used to feed the EDTM module and the first output is irrelevant. We shall set the first argument in function r_pulser_Start() to be 0 to set the rate of both outputs of the pulser generator.
The table showing the correspondence between the pulser rate and the hexadecimal words used in the r_pulser_Start() function can be found by typing the following command in a terminal opened on a computer in the counting house:
>less /adaqfs/home/adaq/vme/rpulser/obs.txt