==How to run DAQ on LEFT HRS (which is also the DVCS one)==
 
==How to run DAQ on LEFT HRS (which is also the DVCS one)==
  
        From a terminal login as "adaq" on adaq1 machine (do "ssh adaq@adaq1" without the quotes)
+
From a terminal login as '''adaq''' on '''adaq1''' machine  
        Password is available on the white board
+
 
        After login to adaq1, type "startcoda" to bring up the runcontrol GUI
+
  ssh adaq@adaq1
        The default configuration is "DVCS", if it is not loaded you can choose it from the menu "configurations->Cool", select "DVCS"
+
 
 +
(Password is available on the white board)
 +
 
 +
After login to adaq1, type
 +
 
 +
  startcoda  
 +
 
 +
to bring up the runcontrol GUI.
 +
 
 +
The default configuration is "DVCS", if it is not loaded you can choose it from the menu "configurations->Cool", select "DVCS"
 +
 
 
         Click "Platform->connect"
 
         Click "Platform->connect"
         Click on "Configure" button
+
 
         Click on "Download" button
+
         Click on "Configure"  
         Click on "PreStart" button
+
 
         Click on "Start" button, and acknowledge "start-of-run" pop-up window
+
         Click on "Download"  
        To end a run click on "End" button
+
 
 +
         Click on "PreStart"  
 +
 
 +
         Click on "Start"
 +
 
 +
and acknowledge "start-of-run" pop-up window
 +
 
 +
To end a run click on  
 +
 
 +
  End
  
 
When starting coda (startcoda command), the DVCS rocs should open automatically, but if not you can try to issue a "dvcsrocs".
 
When starting coda (startcoda command), the DVCS rocs should open automatically, but if not you can try to issue a "dvcsrocs".

Revision as of 12:40, 16 February 2015

Left and the Right DAQ are completly independent of each other.

The Left DAQ setting takes data for the LHRS and the DVCS calorimeter. For the Left DAQ, the data needs to be taken with (regular) LEFT DAQ prescale 9 only. To switch between different type of triggers in the LEFT HRS or on the DVCS calorimeter, one needs to modify prescale on the DVCS trigger module.

How to run DAQ on LEFT HRS (which is also the DVCS one)

From a terminal login as adaq on adaq1 machine

 ssh adaq@adaq1

(Password is available on the white board)

After login to adaq1, type

  startcoda 

to bring up the runcontrol GUI.

The default configuration is "DVCS", if it is not loaded you can choose it from the menu "configurations->Cool", select "DVCS"

       Click "Platform->connect"
       Click on "Configure" 
       Click on "Download" 
       Click on "PreStart" 
       Click on "Start"

and acknowledge "start-of-run" pop-up window

To end a run click on

 End

When starting coda (startcoda command), the DVCS rocs should open automatically, but if not you can try to issue a "dvcsrocs".

How to run DAQ on RIGHT HRS (only for GMP)

       From a terminal login as "adaq" on adaq2 machine (do "ssh adaq@adaq2" without the quotes)
       Password is available on the white board
       After login to adaq2, type "startcoda" to bring up the runcontrol GUI
       The default configuration is "RHRSnoBuff", if it is not loaded you can choose it from the menu "configurations->Cool", select "RHRSnoBuff"
       Click "Platform->connect"
       Click on "Configure" button
       Click on "Download" button
       Click on "PreStart" button
       Click on "Start" button, and acknowledge "start-of-run" pop-up window
       To end a run click on "End" button 


How to kill coda processes

At the terminal of adaq1 (for LHRS) or adaq2 (for RHRS), type

 kcoda

You may also try a

 killdvcsrocs